Wiring To A Cabinet Or A Wall-Mounted Junction Box
GROUNDED NEUTRAL
1. Connect the bare and white appliance cable
wires to the white (neutral) power supply
wire.
2. Carefully check each connection and make
sure that it is secure, and that no bare
wires can short together.
3. Twist a wire connector over the free ends
of the white wires.
4. Position the wires inside the junction box,
and install the cover.
cable from power supply
junction box
red wires
white wire
white and bare
grounding
appliance cable
wires
appliance cable
from cooktop
If Local Codes Permit Connecting Cooktop
Grounding Wire To White (Neutral) Wire In
Junction Box
UNGROUNDED NEUTRAL
1. Connect the white appliance cable wire to
2. Connect the bare grounding appliance
3. Twist wire connectors over the free ends of
4. Carefully check each connection and make
5. Position the wires inside the junction box,
black wires
U.L.- listed
conduit connector
If Local Codes Do Not Permit Connecting
Cooktop Grounding Wire To White (Neutral)
1-13
Cooking Products Service Manual
Original
April, 1996
© 1996 Whirlpool Corporation
the white (neutral) power supply wire.
cable wire to the green grounding power
supply wire.
the white and green wires. IMPORTANT:
Do not connect the bare grounding wire
to the white (neutral) wires in the junc-
tion box.
sure that it is secure, and that no bare
wires can short together.
and install the cover.
cable from power supply
junction box
red wires
white wires
appliance cable
from cooktop
Four-Wire Electrical System
OR
Wire In Junction Box
4321972
Page 1-13
green and bare
grounding wires
black wires
U.L.- listed
conduit connector

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc8700edRc8720ed

Table of Contents