JVC LST0984-001A Instructions Manual page 8

Color video camera
Table of Contents

Advertisement

Connection/Installation
Connection (Continued)
Do not connect DC 12 V and AC 24 V cables at the same time.
Memo
When using a DC 12 V power supply, ensure that the polarities of the
cable are correct.
AC 220 V - AC 240 V (TK-C9201EG/TK-C9301EG)
When using this camera, install it near the socket so that power disconnection
may be made immediately.
Connecting the Monitor
Connect with a 75 K coaxial cable (BNC) such as RG-59.
Connecting the Alarm Input/Output Terminal (TK-C9300U/TK-
C9300E/TK-C9301EG only)
Menu settings may be required depending on the connected equipment. (Refer to
[AUX FUNCTION] in the separate "MENU SETTING".)
The default setting has been set to alarm input (IN:ALARM).
Alarm input terminal
Connect the infrared sensor, door sensor, metal sensor, manual switch sensor
and the like.
To prevent noise from entering the internal circuit, supply non-voltage setting
signal to the alarm input signal.
Do not supply voltage.
Using the menu, you can select whether to set to alarm when the contact is
short (MAKE), or when the contact is open (BREAK).
Supply such that the alarm signal stays at a minimum of 200 ms or more.
Otherwise, the alarm signal may not be recognized.
SEE INSTRUCTION
OFF
D/N AUTO
BLC OFF
ON
LCD
CRT
WIDE-D OFF
ON
MONITOR TYPE
CLASS 2 ONLY
(U TYPE)
ISOLATED POWER
ONLY (E TYPE)
.
Alarm output terminal
Connect to alarm devices such as alarm, indicator, light or buzzer.
The alarm output signal is open collector output and turns ON during an alarm.
(Maximum voltage 16 V, current 30 mA)
This terminal has a polarity. Make sure to connect such that a higher voltage is
output from the + terminal than from the - terminal. Otherwise, it will result in
damages.
.
8
AUX(IN)
MANUAL
VIDEO
GND
OUT
FOCUS
ADJUST
SET
AUX(OUT)
100
GND
Please use a shielded cable.