CLEARANCE TO COMBUSTIBLES

Back...................0"/0mm
Sides..................0"/0mm
Floor...................0"/0mm
Top.....................24"/610mm
Front..................36"/915mm
ELECTRICAL CONNECTION
A 15 AMP, 120 Volt, 60Hz circuit with a properly
grounded outlet is required. Preferably, the
heater will be on a dedicated circuit. Other
appliances on the same circuit may cause the
circuit breaker to trip or the fuse to blow when the
heater is in operation. The unit comes standard
with a 6' (1828mm) long three wire cord exiting
from the rear of the fireplace. Plan the installation
to avoid the use of an extension cord. If an
extension cord must be used, it must be a mini-
mum 16 AWG three wire with grounding type plug
connector and rated no less than 1875 Watts.
LEG ASSEMBLY
WARNING: Electrical
outlet wiring must comply with
local building codes and all
other applicable
regulations to reduce the risk
of fire, electrical shock and
injury.
WARNING: Do not use this
fireplace if any part of it has
been under water. Immediately
call a qualified service
technician to inspect the
fireplace and replace any part
of the electrical system if
necessary.

ELECTRICAL SPECIFICATIONS

Voltage................120 VAC/60Hz
Total Amps...........11.3 Amps
Total Watts...........1500 Watts
Heater Ratings.....1400 Watts
(+5%,-10%)