ALL ELECTRICAL CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN. FAILURE TO COMPLY MAY RESULT IN SERIOUS
INJURY! ALL ADJUSTMENTS OR REPAIRS MUST BE DONE WITH THE MACHINE DISCONNECTED FROM THE POWER SOURCE.
FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY!
POWER SUPPLY
WARNING!: YOUR TILE SAW MUST BE CONNECTED TO A 120V, 15-AMP,
BRANCH CIRCUIT. FAILURE TO CONNECT IN THIS WAY CAN RESULT IN
INJURY FROM SHOCK OR FIRE.
GROUNDING
This Tile Saw must be grounded. If it should malfunction or breakdown, grounding
provides a path of least resistance for electric current, reducing the risk of electric
shock. This Tile Saw is equipped with a cord having an equipment-grounding
conductor and grounding plug. The plug must be plugged into an appropriate
outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
Not all outlets are properly grounded. If you are not sure if your outlet is
properly grounded, have it checked by a qualified electrician.
WARNING!: IF NOT PROPERLY GROUNDED, THIS TILE SAW CAN
CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN DAMP
LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER CORD IS
WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED IMMEDIATELY.
WARNING!: TO MAINTAIN PROPER GROUNDING OF YOUR TILE SAW, DO NOT REMOVE OR ALTER THE GROUNDING PRONG IN ANY
MANNER.
120V OPERATION
As received from the factory, your Tile Saw is ready to run for 120V operation. This Tile Saw is intended for use on a circuit that has an outlet
and a plug which looks like the one illustrated in Fig.1.
WARNING!: DO NOT USE A TWO-PRONG ADAPTOR FOR THEY ARE NOT IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES.
NEVER USE IN CANADA.
EXTENSION CORDS
The use of any extension cord will cause some loss of power. Use the chart Fig.2 to determine the minimum wire size (A.W.G-American Wire
Gauge) extension cord needed. Use only 3-wire extension cords which have 3-prong grounding type plugs and 3-hole receptacles which accept
the tool's plug.
For circuits that are further away from the electrical circuit box, the wire size must be increased proportionately in order to deliver ample voltage to
the Tile Saw motor. Refer to Fig. 2 for extension cord length and size (gauge).
MODEL
Blade diameter
Depth of cut at 45°
Depth of cut at 90°
Table size
Max rip (right/left)
Diameter of arbor
Motor
R.P.M.
Max dimensions (L x W x H)
Weight
ELECTRICAL INFORMATION
& SPECIFICATIONS
WARNING!
PROPERLY GROUNDED OUTLET
CURRENT CARRYING
PRONGS
GROUNDING PRONG
Cord Size in A.W.G.
Tool's
Amperage
Cord Length in Feet
Rating
25
50
100 150
18
16
16
3-6
18
16
14
6-8
18
16
14
8-10
18
16
14
10-12
14
12
12-16
FIGURE 2
KC-3004ST
7"
1 3/8"
1 3/8"
15" x 15 1/2"
14" / 18"
5/8"
3.75 Amp. 110V, 1 phase, 60Hz
3,500
25" x 15 1/2" x 9"
23.5 lbs
FIGURE 1
Wire Sizes in mm 2
Cord Length in Meters
15
30
60
14
.75
.75
1.5
12
.75
1.0
2.5
12
.75
1.0
2.5
12
1.0
2.5
4.0
-
-
-
-
-
120
2.5
4.0
4.0
-
-