Datalogic DS6300 Reference Manual page 38

A high performance laser scanner
Hide thumbs Also See for DS6300:
Table of Contents

Advertisement

2
Figure 29 - IN3/IN4 NPN Input Command using Scanner Power
Input devices can be supplied by either scanner power (VS and GND) or external power
supplies (Vext).
Electrical isolation between the input command logic and the scanner is maintained when
powering the input devices from an external supply voltage (Vext).
The driving logic of the input signals may be powered, for convenience, with the voltage
supply between pins 9 (VS) and 23 (GND) of the 26-pin I/O connector. In this case, however,
the device is no longer electrically isolated.
The voltage available on the 26-pin I/O connector, is physically the same as used to power
the scanner.
The electrical features of these inputs are:
Maximum voltage 30 V
Maximum current 10 mA
Outputs
Three general purpose outputs are available.
Pin
Name
8
OUT 1+
22
OUT 1-
11
OUT 2+
12
OUT 2-
16
OUT 3A
17
OUT 3B
The function of the three outputs OUT1, OUT2 and OUT3 can be defined by the user.
Refer to Genius™ Help On-Line for further details.
24
DS6300
VS
INREF
+ 5V
~
-
+
~
IN3A
+ 5V
~
-
+
~
IN4A
GND
Function
Configurable digital output 1 – positive pin
Configurable digital output 1 – negative pin
Configurable digital output 2 – positive pin
Configurable digital output 2 – negative pin
Configurable digital output 3 – polarity insensitive
Configurable digital output 3 – polarity insensitive
EXTERNAL DEVICE
V
Ground
EXTERNAL DEVICE
V
Ground
DS6300

Advertisement

Table of Contents
loading