Annex3 Error Code List - Omron F39-MC11 Instruction Manual

Setting console
Table of Contents

Advertisement

F3ZN
Sensor
Mode display
Function
CH
(Top row)
SET/
ALL
Fixed blanking
Function
MONITOR
1 to 3
Teach
Manual
ALL
-
ALL
Floating blanking
Function
1 to 3
Floating Beam
Sequential beam
Outermost beam invalid
ALL
-
ALL
Output2
Setting value
-
External indicator
Setting value
output
-
Threshold adjustment
Min. light level
-
Initialization
ID setting
Setting value
-
1 to 3 Error log view
Error log view
COPY
1 to 3
Upload
1 to 3
Download
Bank lock
Bank number
PROTECT
Setting lock
Lock object
Input password
Change password
Old password
New password
Setting limitation
No. of fixed zones
Max. no. of Fixed
beams
Max. no. of floating
beams
- 59 -
Mode display
(Bottom row)
Valid / Invalid
Teaching / Clear
Valid / Invalid (Set each beam)
Send to sensor
Valid / Invalid
1 / 2 / 3 / Clear
Valid / Invalid
Valid / Invalid
Send to sensor
L-on / D-on / Light diagnosis
/ Lockout / Outermost beam /
Specified beam / Blanking
Send to sensor
L-on / D-on / Light diagnosis
/ Lockout
Send to sensor
Threshold value
Send to sensor
Cancel / Send to sensor
0000 to 9999
Send to sensor
Error code
Bank number
Bank number
LOCK / FREE
All / Only F3SN+F3SH / Only
F3ZN / Clear
Input 4 digit number
Input 4 digit number
Input 4 digit number
Clear, 0 to 3
Clear, 1 to 9
Clear, 0 to 3

ANNEX3 ERROR CODE LIST

Error code
A8, AA
Wiring error
Wiring is not performed correctly.
Please confirm a sensor instruction manual and check wiring.
A3
Error of the EDM function
Feed back signal is not returned to EDM line or a relay may be
welding.
Please improve wring or change a relay so that feed back signal is
returned correctly.
A7, 32
Communication error
The communication error has occurred by the wiring error, or a noise.
Please improve installation environment and wiring environment.
When you cannot solve, please contact our sales office.
35 to 38, 27
OSSD error
OSSD outputs are shorted together or OSSD output is shorted to
+24V line, 0V line, or the other I/O line or failure of OSSD output
circuit.
Please improve wiring. When you cannot solve, please contact our
sales office.
A2
Error by interference light
The sensor receives interference light from another sensor. Please
adjust an optical-axis including that of surrounding sensors. In
addition, please do interference light countermeasure as described in
sensor instruction manual.
A0, A1, A4, A5
Incorrect configuration on sensor connection
The model of emitter and receiver differs. When sensor is connected
in series, sensor connection is incorrect. Please check the sensor
model and connection status.
Other codes
Internal error
Irreparable Error has occurred inside the sensor. Please contact our
sales office.