External Device Monitoring - Omron F39-MC11 Instruction Manual

Setting console
Table of Contents

Advertisement

<F3SN, F3SH, F3ZN>
About F3SN and F3SH, it becomes the following displays by the serial
number.
Ext. indicator output
4.E.I.O.
②-1
②-2
Dark ON
Light ON
1.D.ON
2.L.ON
③-1
Send to sensor
SEND
③-2
Setting completed
Error
GOOD
ERR
Go to ①
after 1 sec.
- 29 -
[Enter] Key
Blinking
[Cancel] Key
[Up][Down] Key
②-3
②-4
Light diagnosis
Lockout
3.L.DG
4.L.OU
8.6

External device monitoring

<F3SN, F3SH>
This function can detect malfunction of external device which controls
hazardous area of machine. (e.g. contact welding)
The determination time can be set in respect to the response time of
relay being used. The setting time must be between 100ms to 600ms
and can be set in 5ms increments.
Ext. device monitor
5.EDM
②-1
②-2
Function valid
Acceptable delay time
1.FUN
②-1-1
②-2-1
Function valid
Select time (ms)
ON:Valid
Change delay time
using [UP][DOWN]
[L][R]keys.
(100 to 600 ms;
every 5ms)
OFF:Invalid
Go to ②-2
Go to ②-3
[Enter] Key
Blinking
[Cancel] Key
[Up][Down] Key
②-3
Send to sensor
2.TIM
SEND
②-3-1
Setting completed
300
GOOD
Error
ERR
Go to ①
after 1 sec.
- 30 -