Omron F39-MC11 Instruction Manual
Omron F39-MC11 Instruction Manual

Omron F39-MC11 Instruction Manual

Setting console

Advertisement

Quick Links

F39-MC11
Model
Setting Console
INSTRUCTION MANUAL
Thank you for selecting OMRON product. This manual primarily
describes precautions required in installing and operating the product.
Before operating the product, read this manual thoroughly to acquire
sufficient knowledge of the product. For your convenience, always keep
this manual at hand.
©OMRON Corporation 2001-2003 All Rights Reserved.
PNSPO!
(ver. 3)
Read and Understand this Instruction Manual
Please read and understand this instruction manual before storing,
installing, programming, operating, maintaining, or disposing of the
products. Please consult your OMRON representative if you have any
questions or comments.
Warranty, Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from
defects in materials and workmanship for a period of one year (or
other period if specified) from date of sale by OMRON.
OMRON
MAKES
NO
WARRANTY
EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE
OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES
THAT THE BUYER OR USER ALONE HAS DETERMINED THAT
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF
THEIR INTENDED USE.
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON
SHALL
NOT
BE
INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE
PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT,
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the
individual price of the product on which liability is asserted.
IN
NO
EVENT
SHALL OMRON
WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED,
AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION,
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR
REPAIR.
OR
REPRESENTATION,
OMRON DISCLAIMS ALL OTHER
RESPONSIBLE
FOR
SPECIAL,
BE
RESPONSIBLE
i
FOR

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F39-MC11 and is the answer not in the manual?

Questions and answers

Summary of Contents for Omron F39-MC11

  • Page 1 OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. EVENT...
  • Page 2 PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. - ii - - iii -...
  • Page 3 WARNIG disconnecting the F39-MC11. • When F39-MC is not in use, disconnect it from the sensor. F39-MC must be managed and used only by qualified persons. Operation by un-qualified persons could create a hazardous condition which may lead to a loss of safety function.
  • Page 4: Table Of Contents

    Table of Contents DESCRIPTION ................1 Outline of operation procedure ..........2 Available function and Sensor serial number ......3 RATING ..................4 NOMENCLATURE................. 5 WIRING/CONNECTION ..............7 Mounting branching connector ..........7 Diagram for Wiring of Branching Connector......8 Connecting F39-MC ..............9 POWER ON................. 10 FUNCTION SELECTION..............11 CHANNEL SELECTION ..............
  • Page 5: Description

    DESCRIPTION Outline of operation procedure Shown in the following flow chart. The Setting consol Model F39-MC11 (hereafter referred to as F39-MC) Outline of operation procedure can be connected to Safety Light Curtain Series—Model F3SN, Multi-beam Safety Sensor series—Model F3SH, and Area Scanner series—Model F3ZN.
  • Page 6: Available Function And Sensor Serial Number

    RATING For the sensor having the specific serial number, there are some Models F39-MC11 unavailable functions in the functions of the F39-MC11. Items Check the serial number on the type label of the sensor for both emitter Applicable sensor F3SN, F3SH, F3ZN Series and receiver to make sure available functions for the sensor.
  • Page 7: Nomenclature

    Change mode, increase value DOWN Change mode, decrease value RIGHT digit position down DOWN LEFT digit position up CANCEL ENTER CANCEL To cancel DOWN PNSPO Setting Console ENTER To set CANCEL ENTER F39-MC11 MADE IN JAPAN - 5 - - 6 -...
  • Page 8: Wiring/Connection

    WIRING/CONNECTION Diagram for Wiring of Branching Connector Mounting branching connector ①8Pin female ②8Pin male Mount a branching connector to sensor. The connector can be To sensor To power mounted either on emitter or receiver. supply circuit When mounted on receiver When mounted on emitter Emitter Receiver...
  • Page 9: Connecting F39-Mc

    Insert M12 connector of the cable into Branching connector and the Power supply of F39-MC is shared with that of the sensor. other end into the F39-MC11. The F39-MC turns ON with the power supply of the sensor. When the F39-MC power is ON, it confirms its connection to sensor.
  • Page 10: Function Selection

    FUNCTION SELECTION CHANNEL SELECTION Using [UP][DOWN] keys, select the function. Display of selected When changing the setting of the sensor with the F39-MC, select the function flashes. channel in order to determine which sensor is to be set. Function selecting method is shown below. Selecting channel (CH) method is as follows;...
  • Page 11: Monitor/Set

    MONITOR/SET Changing selected channel when connected to three sensors CAUTION 1ch is selected After the changing the setting of the sensor, a start-up check must (After power on) be conducted. Normal operation can only be allowed after safety is CH(-) CH(+) confirmed.
  • Page 12: Fixed Blanking

    (ii)F3SH Fixed blanking <F3SN, F3ZN> 3.Auxiliary output 4.Ext. i n di c ator output 5.Ext. device monitor 6.Start interlock CAUTION In order prevent access to a dangerous area, fixed barrier guards must be placed in fixed blanked areas. 3.AUX 5.EDM 4.E.I.O.
  • Page 13 <F3SN> <Surveillance mode> ① [Enter] Key F3SN can set up the following operation in consideration of safety. Fixed blanking Blinking [Cancel] Key Setting release at the light receiving condition [Up][Down] Key In case a blanked beam becomes clear, F3SN will automatically 1.FIX invalids fixed blanking function.
  • Page 14 <F3SN, F3ZN> Example of how to set fixed blanking. About F3SN, it becomes the following displays by the serial number. Example1:Set Fixed Blanking using "teaching" ① [Enter] Key Fixed blanking Blinking ②-1-1:Select "1.Fun-on"(Function valid) [Cancel] Key [Up][Down] Key Place an object where you want to be "blanked" 1.FIX ②-2-1:Select "2.tch-Ent"(Beams select)...
  • Page 15: Floating Blanking

    Floating blanking <F3SN, F3ZN> CAUTION Use of floating blanking function involves a change of the safety CAUTION distance. Always recalculate and re-measure the safety distance to confirm that it meets the applicable standards, after the change. Use of floating blanking function involves a change of the safety Failure to do so may cause the machine to fail to stop before an operator distance.
  • Page 16: Auxiliary Output

    Auxiliary output ① Floating blanking [Enter] Key <F3SN, F3SH> Blinking [Cancel] Key [Up][Down] Key This is a non-safety related output used to display a status. 2.FLO This output cannot be used for the purpose of safety. ②-1 ②-2 ②-3 ②-4 ②-5...
  • Page 17 ① [Enter] Key ① [Enter] Key Output #2 Blinking Auxiliary output Blinking [Cancel] Key [Cancel] Key [Up][Down] Key [Up][Down] Key 3.OU2 3.AUX ②-1 ②-2 ②-3 ②-4 ②-1 ②-2 ②-3 ②-4 Dark ON Light ON Light diagnosis Lockout Dark ON Light ON Light diagnosis Lockout 1.D.ON...
  • Page 18: External Indicator Output

    External indicator output <F3SN, F3SH> <F3SN, F3SH F3ZN> ① [Enter] Key Ext. indicator output Blinking [Cancel] Key This is a non-safety related output which can be connected to an [Up][Down] Key optional indicator, such as F39-A01P - . Applicable only to the models which can be connected in series. 4.E.I.O.
  • Page 19: External Device Monitoring

    <F3SN, F3SH, F3ZN> External device monitoring <F3SN, F3SH> About F3SN and F3SH, it becomes the following displays by the serial number. This function can detect malfunction of external device which controls hazardous area of machine. (e.g. contact welding) ① [Enter] Key Ext.
  • Page 20: Start Interlock

    Start interlock Restart interlock <F3SN, F3SH> <F3SN, F3SH> When this function is ON, the outputs remain in the OFF-state (i.e. When this function is ON, the outputs remain in their OFF-state (i.e. interlock state) after power ON. Interlock state can be released by a interlock state) when sensor is interrupted.
  • Page 21: Threshold Adjustment

    Threshold adjustment 8.10 Setting initialization <F3ZN> <F3SN, F3SH, F3ZN> This function returns the sensor setting to their default value. This function enables to adjust threshold value of F3ZN. ① [Enter] Key Upper row displays current minimum light level (minimum value Initialization Blinking throughout all beams in the sensor), and lower row displays current...
  • Page 22: Id Setting

    8.11 ID setting 8.12 Threshold teach <F3SN, F3SH, F3ZN> <F3SN, F3SH> ID number can be set specific to each sensor. This function can be used to display receiving light level of sensor or The possible setting number range is between 0000 and 9999. adjust ON-threshold level to most suitable value.
  • Page 23 Individual max light level display mode One-point advice: The maximum receiving light level of the selected beam is Adjust beams of the sensor with this function so that the displayed. minimum receiving light level becomes higher. By doing this, the The beam number is displayed on the top row.
  • Page 24: Error Log View

    ON threshold level obtained by calculation is written in a sensor. <F3SN, F3SH, F3ZN> When the writing is failed, check connecting condition between the sensor and the F39-MC11 and start from the first. The error log recorded in sensor is displayed. Go to 1. display for receiving The error log is written with error codes.
  • Page 25: Copy

    COPY Upload (Copy Sensor data to F39-MC) This function allows you to copy settings of one sensor and transfer Copy the setting data of one sensor to the bank of F39-MC. them to another sensor. The settings which can be changed in Select <1.U.Ld>...
  • Page 26: Download (Copy F39-Mc Data To Sensor)

    Download (Copy F39-MC data to Sensor) Bank Lock (Prohibit overwriting to bank data) To prohibit overwriting to a bank that has been stored with the setting WARNING data of the sensor, select this function by following means; After the changing the setting of the sensor, a start-up check must Select <3.b.Lc>, then press [ENTER] key to enter Bank lock mode.
  • Page 27: Protect

    10 PROTECT 10.1 Setting lock Prohibit setting change. Select from [Lock all sensors], [Lock only F3SN+F3SH], [Lock only F3ZN] or [Unlock all sensors]. WARNING A password (4 digit number) is required to change locked status. F39-MC must be managed and used only by qualified persons. Operation by un-qualified persons could create a hazardous When locked, the following is prohibited;...
  • Page 28: Change Password

    We strongly recommend to use with password other than “0000”, and with Setting lock function. This will prevent unauthorized setting change by un-qualified person. <Note > Please remember changed password. If you forget, please contact OMRON. - 47 - - 48 -...
  • Page 29: Disconnect F39-Mc

    11 DISCONNECT F39-MC ① [Enter] Key Setting limitation Blinking After the setting has completed, be sure to disconnect cable and [Cancel] Key F39-MC before normal use. [Up][Down] Key 3.LMT Operation procedure; 1. Disconnect F39-MC and cable from branching connector. 2. Attach connector cap to branching connector. ②-1...
  • Page 30: Mc11 Error Codes

    Cause: Teaching is not completed with a blocked beam. terminals or excessive Remedy: Teach with one or more beams blocked. noise does not exists. C004 EEPROM error Contact OMRON. EEPROM data been corrupted. C005 F39-MC destructed Contact OMRON.
  • Page 31: Annex1 Index

    ANNEX1 INDEX Terms Explanation Light ON Output ON when detection area is clear. In case series (Auxiliary output, output2, connected, output ON when all sensors’ detection area is clear. Terms Explanation Ext. indicator) Auto reset mode [F3SN, F3SH] Lockout output Output ON when the sensor is in lockout condition (i.e.
  • Page 32: Annex2 Function List (According To Sensor Type)

    Terms Explanation ANNEX2 FUNCTION LIST (according to sensor type) Start interlock function [F3SN, F3SH] Outputs remain in the OFF-state (i.e. Interlock state) after power F3SN ON. Interlock state can be released by a manual reset when there are no obstructions in the detection zone. Sensor Mode display Mode display...
  • Page 33 PROTECT – Setting lock Lock object All / Only F3SN+F3SH / Only F3SH F3ZN / Clear Sensor Mode display Mode display Input password Input 4 digit number Function (Top row) (Bottom row) – Change password Old password Input 4 digit number SET / Auxiliary output Setting value...
  • Page 34: Annex3 Error Code List

    F3ZN ANNEX3 ERROR CODE LIST Sensor Mode display Mode display Function (Top row) (Bottom row) Error code Contents and remedy SET/ Fixed blanking Function Valid / Invalid A8, AA Wiring error MONITOR 1 to 3 Teach Teaching / Clear Wiring is not performed correctly. Manual Valid / Invalid (Set each beam) Please confirm a sensor instruction manual and check wiring.
  • Page 35: Annex4 Function Setting Card

    FUNCTION SETTING VALUE DENMARK OMRON ELECTRONICS A/S INDONESIA Fixed blanking Function Valid/Invalid Odinsvej 15 DK-2600 GLOSTRUP Denmark OMRON ASIA PACIFIC PTE. LTD. Blanked beam ________________ (List selected beams) Phone: 45-43-44-00-11 / Fax: 45-43-44-02-11 INDONESIA REPRESENTATIVE OFFICE GRAHA Floating blanking Function Valid/Invalid PRATAMA FLOOR3A, JL MT HARYONO KAV.

Table of Contents