Subaru RGX2900 Instructions For Use Manual page 20

Generator
Hide thumbs Also See for RGX2900:
Table of Contents

Advertisement

Style
WARNING
To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn it
clockwise to the lock position.
Be sure to ground the generator if
the connected electrical device is
grounded.
NOTE :
When the AC circuit breaker turns off during operation, the generator is over loaded
or the appliance is defective. Stop the generator immediately, check the appliance
and / or generator for overloading or detect and have repaired as necessary by
SUBARU Industrial Power Products dealer or service shop.
[ CAUTION ]
The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit
Interrupter). GFCI shuts off the output current from the duplex 120V
receptacle when a ground fault occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.
Ampere
Receptacle
NEMA
up to 20A
5-20R
NEMA
up to 20A
L14-20R
NEMA
up to 30A
L5-30R
NEMA
up to 30A
L14-30R
TABLE 1
- 15 -
AC plug
Description
GFCI (Ground Fault
Circuit Interrupter)
NEMA
5-20P
Receptacle,
duplex(REC1)
Locking
NEMA
L14-20P
Receptacle(REC2)
NEMA
Locking
L5-30P
Receptacle(REC3)
Locking
NEMA
L14-30P
Receptacle(REC4)
TWIST