Style
WARNING
■
To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn it
clockwise to the lock position.
■
Be sure to ground the generator if
the connected electrical device is
grounded.
NOTE :
When the AC circuit breaker turns off during operation, the generator is over loaded
or the appliance is defective. Stop the generator immediately, check the appliance
and / or generator for overloading or detect and have repaired as necessary by
SUBARU Industrial Power Products dealer or service shop.
[ CAUTION ]
The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit
Interrupter). GFCI shuts off the output current from the duplex 120V
receptacle when a ground fault occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.
Ampere
Receptacle
NEMA
up to 20A
5-20R
NEMA
up to 20A
L14-20R
NEMA
up to 30A
L5-30R
NEMA
up to 30A
L14-30R
TABLE 1
- 15 -
AC plug
Description
GFCI (Ground Fault
Circuit Interrupter)
NEMA
5-20P
Receptacle,
duplex(REC1)
Locking
NEMA
L14-20P
Receptacle(REC2)
NEMA
Locking
L5-30P
Receptacle(REC3)
Locking
NEMA
L14-30P
Receptacle(REC4)
TWIST