Table 57 Maintenance > Power Management (continued)
LABEL
Minimum UPS
Capacity
Apply
Power On After
Power Failure
Keep Former
Status
Always Power
On
Always Power
Off
Apply
Power On/Off Schedule
Enable Power
Control
Schedule
Apply
NSA-220 Plus User's Guide
DESCRIPTION
When you use an APC Uninterruptible Power Supply (UPS) with a USB
connection to the NSA, the NSA shuts itself down if the APC UPS's
battery charge gets down to the percentage you specify in this field. This
allows the NSA to shut down properly and avoid data loss caused by a
power failure when the UPS stops supplying power.
A setting around 50% is recommended. A setting close to 100% is not
recommended since it would cause the NSA to shut down whenever the
UPS is charging. A setting close to 0 is also not recommended since the
UPS would not have enough power to allow the NSA to shutdown
properly.
Click this to save your changes in this section.
Select an option to set whether or not the NSA restarts when the power
is restored after a power failure.
Select this option to have the NSA automatically restart only if it was
operating when the power failed. The NSA remains off if it was already
off when the power failed.
Select this option to keep the NSA operating as much of the time as
possible. The NSA restarts automatically even if it was turned off when
the power failed.
Select this option to keep the NSA from automatically restarting when
the power is restored after a power failure. This is a computer's
"traditional" behavior. Select this if you have other servers such as a
domain controller or DNS server that you want to start or check after a
power failure before the NSA turns on.
Click this to save your changes in this section.
Select this option to have the NSA turn itself off and on or reboot
according to the schedules you configure.
Click Edit to go to the screen where you can configure the power control
schedules.
Click this to save your changes in this section.
Chapter 11 Maintenance Screens
209