Elan Z-630 Series II Installation Manual

Elan Z-630 Series II Installation Manual

Preamp controller
Hide thumbs Also See for Z-630 Series II:
Table of Contents

Advertisement

S
II
ERIES
PreAmp Controller
INSTALLATION A A ND
HOMEOWNERS M M ANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Elan Z-630 Series II

  • Page 1 ERIES PreAmp Controller INSTALLATION A A ND HOMEOWNERS M M ANUAL...
  • Page 2 5.4 Telecomm ....... . .38 © ELAN Home Systems 2002 • All rights reserved. 3/02...
  • Page 3 The Z•630 is also available in a rack mount version––the Z•631. As a manufacturer, ELAN strives to provide you with excellent service after the sale. If you have any questions or comments concerning the performance, installation or features of the Z•630 PreAmp Controller, please call the ELAN...
  • Page 4 E L A N H O M E S Y S T E M S INSTALLATION MANUAL ERIES © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 4...
  • Page 5 This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause unde- sired operation. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 5...
  • Page 6 VIA! Panel, K K eypad, o o r I I R C C ontrollable Whether it’s from a hand-held remote control, an ELAN in-wall Keypad, or VIA! Touch Panel, the Z•630 Keypad/Infrared interface allows you to easily select a source, adjust the volume, and enjoy sound in any room of your home.
  • Page 7 Music-O O n-H H old The Music-On-Hold output jack provides an easy way to send music from the Z•630 to the ELAN Z•600 Comm Controller or any phone system that has a music-on-hold input. What is a Z•600 Comm Controller? Keep reading...
  • Page 8: Front View

    1% Harmonic Distortion DIMENSIONS (HxWxD) TYPICAL INPUT LEVEL.....300mV to 2V RMS (Line Level) Freestanding.........1.75” x 17” x 8” Rackmount..........1.75” x 19” x 8” BASS/TREBLE GAIN LEVEL....+/-12dB, 2dB Step Size © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 8...
  • Page 9: Gain Adjustment

    Adjusts the Music-On-Hold output level of Source #1 going to the Adjusts the sensitivity level needed to automatically trigger a Music-On-Hold input on a phone system or the ELAN Z•600 page from a powered microphone (see Z•630 Commercial Comm Controller.
  • Page 10 Bass and Treble. • The LOUDNESS feature can be turned on or off inde- pendently in each zone. To reset, press EQ FLAT. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 10...
  • Page 11 E L A N H O M E S Y S T E M S INSTALLATION MANUAL ERIES © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 11...
  • Page 12 (hiss) that may be heard “pop” may be heard through the speakers in that zone.) through the speakers when the system is off, and will also © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 12...
  • Page 13 Z•100’s will be set to Zone 1. (see Z•Pad installation manual for details) Figure 3.2 - A Z•630 and Z•660 distributing audio to two separate rooms in stereo within a single zone. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 13...
  • Page 14 Y - Cord to the UP position to FIX the line outputs of zones 2 and 3 Figure 3.3 A three zone system utilizing volume controls in the sub-zones. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 14...
  • Page 15 4x position if utilizing 8 Ohm speakers. 8x position if utilizing 4 Ohm speakers. Figure 3.4 - Using ELAN VMO Volume Controls to distribute audio (in mono) to four separate rooms within one zone. © ELAN Home Systems 2002 • All rights reserved. 3/02...
  • Page 16 Doorbell has ended. Figure 3.5 - Utilizing a Z 025 to override the speaker-level distributed audio feed when a local source (TV) is activated. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 16...
  • Page 17 Figure 3.6 - Z•Series connections enabling a MAIN Zone and a Sub-Zone to reproduce audio from Zone 1 of the Z•630, speaker-level audio from the “local” TV, as well as ELAN Page and Doorbell audio. © ELAN Home Systems 2002 • All rights reserved. 3/02...
  • Page 18 DND enabled so the partons will not hear the Paging. Additionally, Impedance Magnifying volume controls are used to enable two pairs of 8 Ohm speakers to be connected in parallel and still show the amp an 8 Ohm load. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 18...
  • Page 19 If using a wire manage- ment center like the ELAN BINT2000 to pull all of your wiring to, try to install it in an easily accessible and centrally located part of the home.
  • Page 20 Zone a a nd S S ub-Z Z one S S cenarios The buffered zone outputs on the Z•630 make it easy to configure stereo or mono zones and sub-zones. If you are also using ELAN’s Z•660 Multi-Channel Power Amplifier, its buffered inputs and loop outputs may be combined with those of the Z•630, give you virtually limitless zone configuration options.
  • Page 21 H O M E S Y S T E M S INSTALLATION MANUAL ERIES ERIES YSTEM AND IRING EQUIREMENTS (VSE/VSO/VMO) (x4) DSC2000/DS1500/1550 Figure 4.3 - ELAN Z Series system wiring. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 21...
  • Page 22 3. Simply duplicate the connections shown if or home theater). utilizing additional Z•630s. 4. See page 9 for multiple Z•630 DIP Switch settings. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 22...
  • Page 23 (i.e. source input 1 = IR port 1, etc.). An IR emit- from reaching the other source components. ter (ELAN IR2040) should be plugged in to the appropriate Single Z Z 630 I I R Emitter C C onnections Multiple Z Z 630 I I R Emitter C C onnections Figure 5.3 - Using the Z•630’s IR LOOP IN/OUT to “daisy-chain”...
  • Page 24 Additionally, if multiple Z•630s are used, the “IR ALL” ports source components, and the ELAN Z•630. on the AUX Z•630s may be utilized to control additional source components from any zone on any chassis. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 24...
  • Page 25 NOTE: If utilizing Z•025 Audio Detect Modules (see page 27) an external 12VDC plug-in power supply (ELAN Z•027) must be used. Each ELAN 12VDC plug-in power supply will power up to three Z•025s. A maximum of six Z•025s per Z•630 (24 per quad Z•630 system) may be used.
  • Page 26 ERIES 5.6 Z PAD C ONNECTIONS Both the Z•630 and the ELAN Z•PADs utilize the RJ-45 RJ-45 Interface Cable. Independent runs of 22/24 gauge, quick connect plugs. To save time and eliminate potential 4 twisted-pair telephone wire (or standard CAT5) are used termination problems, we strongly recommend the use of to connect to the C45P plugged into each Z•PAD and the...
  • Page 27 PZ6 Precision Panel for quick and easy Z System wire terminations. See the PZ6 Manual and page 28 of this doc- ument for details ELAN Z 027 12VDC Regulated Power Supply © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 27...
  • Page 28 PZ6. Just match up every Z•PAD and Door connect ELAN Z•Series components. Previously, Speaker Assembly wire to the corresponding numerous 'butt-splices' were required to connect connector and punch it down! © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 28...
  • Page 29 RCA-to-F Barrel Connectors for Video Eight RCA-to-F barrel connectors enable easy connection of all your coax wire runs to the Z•880 Video Controller or other video distribution components. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 29...
  • Page 30 Z•630 first, then looped out from the MAIN Z•630 to the 8. Connect the Zone Outputs of each Z•630 to the amp AUX Z•630s (see SOURCE CONNECTIONS on page channels dedicated to each zone (not shown). 22). © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 30...
  • Page 31 Z 630’s WHEN NOT USING A PZ6. The P&DB Control wires are to be paralleled together and connected to pin 1 of the Z 600 Comm Controller. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 31...
  • Page 32 PZ6s, the diagram to the right details the connec- tions of the RS485+, RS485 -, Z 600Page/Doorbell, and Ground between the two PZ6s. P&DB GROUND P&DB PZ6 #2 © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 32...
  • Page 33 When linking two PZ6s together to support a multiple chassis Z 630 system with a single Z 600 Comm Controller, PZ6 #2’s Z 600 RJ-45 jack inputs are not used. Z 630 #4 (Zones 10-12) © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 33...
  • Page 34 Page and Doorbell as well as Music-On-Hold signals). NOTE: The above mentioned connections may be quickly and easily terminated using the PZ6 Precision Panel . © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 34...
  • Page 35 2. ONLY the MAIN Z 630’s Music-On-Hold Output should be sent to the Z 600’s MOH Input. NOTE: The above mentioned connections may be quickly and easily terminated using the PZ6 Precision Panel . © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 35...
  • Page 36 1. Zone is in Do-Not-Disturb 1. Press *, MUTE on the Z•100 or DND zone in a constant slow wink on the Z•030 hand-held remote (see pages 10) © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 36...
  • Page 37 1. See pages 31& 32 In a multiple Z•630 system––no two Z•630s not made or mis-wired. Wholehouse Music feature, System ON/OFF turns on/off one Z•630 but no the other. © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 37...
  • Page 38 Page or Door delay amplifier with one that does not have Chime is initiated a power up delay (such as the ELAN Z•660) © ELAN Home Systems 2002 • All rights reserved. 3/02 Page 38...
  • Page 39: Limited Warranty

    This warranty shall not apply (a) to equipment not manufactured by ELAN, (b) to equipment found to have been installed by other than an authorized ELAN installer, (c) to installed equipment which is not installed to ELAN’s specifications, (d) to equipment found to have been repaired or altered by others than ELAN, (e) to equipment found to have been subjected to negligence, accident, or damage by circumstances beyond ELAN’s control, including, but not lim-...

Table of Contents