HONEYWELL 7000 SOLID STATE ALARM SYSTEM
Keypad Display
Audible
System Off
None
Mode
None
Alarm
ON
Fire Alarm
On (External
delayed for 15
seconds)
Police Alarm
On or Silent
Special Alarm
On or Silent.
Message
System Trouble
ON
Ac Power Failure
None
Low Battery
Low tone once a
minute.
Fire Trouble
Low tone
repeating.
Comm CSC
Low tone once a
Failure
minute.
RFEM Trouble
Low tone once a
minute.
ON Watch
Low tone when
tripped.
Pool Point
On for 30 seconds
if away.
Horn Failure
Low tone
repeating.
Emergency System Shutoff
This procedure will completely disable your entire security
system including the 24 hour protected points, the display
Keypads, and outputs.
Use this procedure only as a last resort if:
1. All efforts to turn off the audible alarms fail, or
2. You cannot disarm the security portion of the system by
any other means, or
3. You want to turn off your System 7000 System for any
other reason.
To shut off the system, unlock and open the Control Panel.
Locate the POWER switch near the right end of the circuit
board. Slide the switch to the OFF position.
IMPORTANT
Call the Honeywell Customer Service
Center immediately, provide your passcard
number and describe the problem.
69-1192—1
Table 11. Keypad LCD and LED response to system operation.
Keypad LED
Left
Right
Off
off
Off
Off
Off
On
Off
Off
Off
Off
off
Off
off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
On
Off
Off
Comments/Interpretations
System in Standby Mode; 24-Hour Points and Fire active.
System in selected Mode.
System in Alarm Mode; see second line of display for alarm type.
System in Alarm Mode; see second line of display for alarm type.
System normal if silent; otherwise in Alarm.
System displays Alarm; see second line of display for alarm type.
Message identifies type of trouble; see message.
Problem displayed; resets when power restored.
Problem displayed; resets when battery replaced.
Problem displayed until circuit restored.
Problem displayed until message received at CSC.
Message displayed until RF service restored.
Point ID Message on for 10 seconds.
Can be ON-WATCH or Armed.
Problem displayed; reset when problem resolved and password
entered.

CHECKOUT

System Installation Test
Local Test Sequence
NOTE: After performing this test and verifying that the
system is working properly, repeat the test with the
customer/home-owner to show him how that the
system operates as intended.
1. Power up the system and verify the KEYPAD(s) are
displaying MASTER ARM .and both LED's are OFF.
2. Verify there were no alarm audibles. (Hardwire points in
the alarm state will go into alarm within 45 seconds
after power-up, Fire after 20 seconds).
3. With the arrow keys verify that all points are normal. If
any are open , correct and proceed.
4. Enter a valid passcode and verify that the System goes
into the default Mode (disarmed).
5. Push the MODES key and select a mode with points in
ON WATCH. (If some points in this mode are
programmed for ALARM, they will go into ALARM.)
24