3.3

Specification tables

Model
Running modes
Running ambient air temp.
Outlet Water Temp.
Minimum Inlet Water Temp.
Maximum Inlet Water Temp.
Power supply
IP rating
Storage size
Water heating
Unit
Sound pressure level at 2 m
Refrigerant type/Mass
Max. refrigerant circuit pressure
2)
PTR valve setting
Throttling type
System protection
Air flow
Compressor
Fan motor
Water connections
E-heater
Table 2
1) EN255-3, water inlet 15 °C, air at 15 °C
2) PTR valve power capacity: 10 kW
Compress 3000 DW FO
1)
Heating capacity
1)
Max. input
1)
COP
1)
Max. current
Dimension (D×H)
Packing (W×H×D)
Net/gross weight
Model
Type
Brand
Input
Model
Brand
Input
Speed
Water inlet
Water outlet
Max. water working
PTR valve joint
Max inlet pressure
Heat exchanger
Rated power input at 240 V
Rated current at 240 V
HP 270-1E 0 FOV/S...
Heat Pump Only Mode
°C
°C
°C
°C
Ph-V-Hz
1ph / 230V-240V / 50 Hz
IP
ltr
kW
kW
-
A
mm
mm
kg
dB (A)
kg
kPa
kPa
Thermal expansion valves
High pressure switch, Temperature limiter
3
m
/h
W
W
r/min
kPa
kPa
Double wall plate heat exchanger
kW
A
Appliance details | 9
+3 °C/+40 °C
60 °C - 65 °C
3 °C
70 °C
X4
270
1.5
0.6
3.3
2.5
670 x 1840
770 x 770 x 2050
130
43
R134a / 0.375
2700
1000
350
WHP01900
Rotary
Highly
700
W1G230EB
EBM Papst
28
1500
¾ BSP inch
¾ BSP inch
1000
½ BSP inch
800
1.8
7.8
6 720 801 244 (2013/08)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Compress 3000 dw fo hp 270-1e 0 fov/s

Table of Contents