2.10 Specification

Technical features
Performance
Nominal Gas Consumption
Minimum gas consumption
Efficiency at 100% of nominal load
Gas supply data
Gas supply pressure (flowing)
Natural gas (when operating)
Universal LP gas (when operating)
Water supply data
Maximum permissible pressure (static)
Minimum operating pressure
Start-up flow
Maximum flow, corresponding to a temperature increase of 25 °C
Maximum inlet temperature
Electrical circuit
Power supply voltage
Frequency
Maximum power consumption
Appliance enclosure rating
General data
Weight (unpacked)
Height
Width
Depth
Table 5
Optiflow Professional – 6 720 810 560 (2017/11)
Units
GWH12
MJ/h
90.0
MJ/h
11.9
%
82.4
kPa
1.13
kPa
2.75
kPa
1000
kPa
100
l/min
2.0
l/min
12.0
°C
50
V
230
AC
Hz
50
W
228
kg
10
mm
570
mm
300
mm
170
Product details
GWH16
GWH20
120.2
149.0
18.0
18.0
82.4
82.4
1.13
1.13
2.75
2.75
1000
1000
100
100
2.0
2.0
16.0
20.0
50
50
230
230
50
50
228
228
IPX4D
11
12
570
570
364
364
175
175
11

Advertisement