Servicing Intervals

If fittings will not take grease, remove and clean thoroughly. Also clean lubricant passageway.
Replace fitting if necessary.
8 Hours or Daily: Telescoping Tubes and Quick Disconnect 20 Hours
1.
Lubricate PTO driveline (7 locations).
ALERT
80 Hours or Once a Season:
2. Lubricate rotor driven end bearing (1 location)
3. Lubricate rotor drive end bearing (1 location).
4. Lubricate chain drive bearing (1 location).
- use 3 squirts only.
- push grease in gradually
When using the safety chains supplied with the PTO shaft,
the shield bearings must be kept lubricated.