TK-260G/(N)/270G/(N)
8-2. Channel Setting Mode
This is a mode for making channel settings with the panel
keys without using the FPU.
Pressing [Side2] when "SELF" is displayed, sets Channel
Setting Mode.
Select an item set using [3] then change the selection with
the encoder.
The data displayed using [2] is stored in the memory and
then proceeds to the next item. Pressing [3] proceeds to
the next item without storing it in the memory.
Press [Side2] to set the display to "SELF" and return to reset
(default) status.
All channel data is cleared when pressing [2] key with the
blank RX frequency.
No. Function Choices Display
Select
1-128
Channel
Select
1-128
Group
1 RX frequency Step 2.5kHz-1MHz STP_250 Display when an item is selected
Blank
100.0000-
550.0000MHz
2 Rx Signaling OFF
QT 67.0-250.3Hz
(EIA Mode)
QT 67.0-250.3Hz
(0.1Hz Step Mode) QT_250.3*
DQT 000-777 (Normal) DQT000N*
(1 Step Mode)
DQT 023-754 (Normal) DQT023N
(Standard Table Mode) DQT754N
DQT 000-777 (Inverse) DQT000I*
(1 Step Mode)
DQT 023-754 (Inverse) DQT023I
(Standard Table Mode) DQT754I
3 TX frequency Step 2.5kHz-1MHz STP_250
Blank
100.0000-
550.0000MHz
4 TX Signaling
5 Option Signaling OFF
DTMF
2-TONE
6 ID
000-
9999999999
Blank
12
REALIGNMENT
Remarks
_1-_1._
[3] : Group selection/
_1-128._
Channel selection change
_1.-_1_
128.-_1_
STP_1000 or when a step is changed
(about 0.5 seconds)
[
] Step change
VHF : 2.5, 5.0,6.25,7.5kHz,1MHz,Step
R. ———— [Side1] : Freq On/Blank switching
R.100.0000 The rightmost dot indicates
50Hz digit (On=5; Off=0).
————
[Side1] : Off/QT/DQT switching
QT_67.0_ [
] : Mode switching
°
QT_250.3_ [
] : Normal/Inverse
QT_67.0*
switching
DQT777N*
DQT777I*
Same as RX frequency.
STP_1000
T. ————
T.100.0000
Same as RX signaling.
NONE____
Default
DTMF____
2TONE___
___ID___
Display when an item is selected
(about 0.5 seconds)
12345678
Display of the current setting
(If it is 8 or more digits, scroll it.)
——987 Display when a code is input
(Input it with DTMF key.)
————
[Side1] : Data clear
No. Function Choices Display
7 Busy Channel NO
BCL_NO__
Lockout
Type 1
BCL_1___
Type 2
BCL_2___
8 Beat shift No
SHFT_NO_
Yes
SHFT_YES
9 RF Power High Power PWR_H___
Low Power PWR_L___
10 Wide/Narrow Wide
WIDE__ K, K2, M, M2 destination only
NARROW NARROW__
Wide 5K Wide
-W5K
Wide 4K Semi wide -W4K
11 Scan
DELETE
SCAN_DEL Not used for TK-260G
Delete/ADD ADD
SCAN_ADD
12 Priority
No
P.CH_NO__ Not used when (Scan) Priority is not Fixed.
Channel
Yes
P.CH_YES_
13 Home Channel No
H.CH_NO__ Not used when Home Channel is
Yes
H.CH_YES_ not set in Key Assignment.
14 Compander No
COMP_NO_ Not used when Wide is selected.
Yes
COMP_YES
15 PTT ID
OFF
P.ID_OFF
Begin of TX P.ID_1
End of TX P.ID_2
Both
P.ID_3
16 Begin of
000-
_BOT_ID_
TX ID
9999999999999999
12345678
——987
Blank
————
17 END of
000-
_EOT_ID_
TX ID
9999999999999999
12345678
——987
Blank
————
Remarks
Default
BCL_YES for K, E, (N)E, K2 type
N/A for K, E, (N)E, K2 type
Default
Default
E destination only
Default
Not valid if Dial ID =Disable and
PTT ID=OFF, or EOT is set.
Display when an item is selected
(about 0.5 seconds)
Display of the current setting
(If it is 8 or more digits, scroll it.)
Display when a code is input
(Input it with DTMF key.)
[Side1] : Data clear
Not valid if Dial ID =Disable and
PTT ID=OFF, or EOT is set.
Display when an item is selected
(about 0.5 seconds)
Display of the current setting
(If it is 8 or more digits, scroll it.)
Display when a code is input
(Input it with DTMF key.)
[Side1] : Data clear