LOCATION

Prior to installation, ensure that the local distribution
conditions (nature of the gas and gas pressure) and
adjustment conditions are compatible.
adjustment conditions for this appliance are stated
on the data badge which is fitted inside the bottom
burner door.
When choosing a location for this appliance you
must have:
(a) S u fficient room
clearances), a satisfactory flue, and an
adequate air supply for correct combustion and
operation (see Ventilation & Combustion Air
Requirements).
(b) Adequate space for maintenance and air
circulation.
(c) Solid floor or base of non-combustible material
which is capable of supporting the total weight.
(See Technical Data).

HEARTH CONSTRUCTION

When a non-combustible floor surface is not
available then we recommend that the cooker be
placed on a slab of pre-cast concrete 40mm (1
deep or a slab of other insulating material. This
hearth must extend 150mm (6") to either side of the
appliance and 225mm (9") to the front.

ELECTRICAL SUPPLY

All wiring external to the appliance must conform to
the current BS 7671, B.S. 7462, Safety Document
635 ETC: Part 1 Section 5.4.6. & the Electricity at
Work Regulations. The cooker requires a 230V -
240V, 50Hz supply. Connection of this appliance to
the mains supply must be through a moulded on
plug top (with a 3A fuse) which is fitted to the
appliance in accordance with EN 60335, Consumer
Protection: SI 1994 No. 1768 (plug and sockets etc)
Safety Regulations 1994.
Always install in accordance with current local
wiring regulations.
WARNING: THIS SUPPLY AND COOKER MUST
(
BE EARTHED
Refer to B.S. 7430 :
Protection of Earthing).
Where a risk of low voltage (below 190 volts) can
occur, a voltage sensitive device should be fitted to
prevent start up of the burner so as not to endanger
the installation. Primary fuse is located at rear of
control box.
for the installation (see
Code for
To isolate the appliance completely unplug from the
mains socket. Always ensure that this socket is
easily accessible and close to the appliance.
Persons in charge of this appliance should be aware
The
of this socket outlet position.

COOKER CLEARANCES

Minimum clearances to combustible materials:
6" (150mm) to either side
2" (50mm) to rear
36" (915mm) above
48" (1220mm) to front (See figs 2 & 3)