FEATURE
Hot Plate
Roasting Oven
Simmering Oven:
This appliance has been tested and approved in accordance with the Gas Appliance Directive (90/396/EEC), the
Low Voltage Directive (72/23/EEC) and the Electromagnetic Compatibility Directive (89/336/EEC) as amended.
FUELS:
PRODUCT IDENTIFICATION:
COUNTRY OF DESIGNATION:
GAS TYPES:
MAINS SUPPLY:
SUPPLY FUSE RATING:
IONISATION CURRENT:
I.P. PROTECTION DEGREE:
ELECTRICAL INPUT:
MAINS GAS PRESSURE:
MAXIMUM FLUE RESISTANCE:
GAS RATES
GROSS HEAT INPUT:
MANIFOLD PRESSURE -
SPACE HEATING -
COOKER WEIGHT:
MAINS GAS PIPE:
Whilst the primary air and gas rate on this appliance have been set, combustion tests and the gas rating must be
undertaken, during commissioning and adjusted accordingly.
NOTE: This appliance must be installed in accordance with the regulations in force and only used in a well
ventilated location. Read the technical instructions before installing this appliance. Read the user's instructions
before lighting this appliance.
ADDITIONAL TECHNICAL DATA FOR DHW MODELS:
MANIFOLD PRESSURE:
MAX. DHW BOILER WORKING PRESSURE:
TEST PRESSURE IN DHW BOILER:
OPERATING TEMPERATURE LIMIT IN DHW
BOILER:
DHW BOILER CAPACITY:
DHW BOILER MATERIAL:
COOKER WEIGHT:
DHW BOILER OUTPUT:
METRIC (mm)
550W x 323L
390W x 310H x 406D
390W x 220H x 406D

TECHNICAL DATA

2nd Family, Natural Gas or 3rd Family, L.P.G.
63AT5325
G.B., I.E., B.E., A.T., D.K., E.S., F.I., I.T., P.T., S.E. &
F.R.
N.G.:
L.P.G.: I
230V - 240V, 50 Hz, A.C.
3 A
Minimum of 7µA
IP 20
90 watts.
NATURAL GAS
20 mbar (8" wg)
0.8 mbar (0.32" wg)
1.48m
15.8 kW (53,909 Btu's/hr)
6.4 mbar (2.56" wg)
1.70 kW (5,800 Btu/hr)
356 Kgs 783 lbs
Installation of gas pipe to be carried out in accordance
with BS 6891.
N.G.: 6.4 mbar (2.56"wg).
L.P.G.: 4.1 mbar (1.65" wg).
28 p.s.i.
40 p.s.i.
o
96
C (194
10 Litres (2.2 gallons)
3mm Stainless Steel
360 kg (790 lbs)
3.8 kW (13,000 Btu's) (Continuous Running)
4
IMPERIAL (inches)
5
21
/
8
1
15
/
4
1
15
/
4
I
, G20, 20 mbar (I.E., G.B., A.T., D.K.,
2H
E.S., F.I., I.T., P.T., & S.E.)
, G31, 37mbar (I.E., G.B., B.E., F.R., E.S.,&
3P
P.T.)
3
3
/hr(52.26 ft
/hr)
o
F)
3
W x 12
/
L
4
1
W x 12
/
H x 16D
4
3
W x 8
/
H x 16D
4
L.P.G.
37 mbar (14.8" wg)
0.7mbar (0.28" wg)
3
3
0.59m
/hr (20.8 ft
/hr)
15.8kW (53,909Btu's/hr)
4.6mbar (1.85" wg)
1.7 kW (5,800 Btu's/hr)