ClimateMaster ATC32U02 iGate Installation Manual page 7

Communicating
Hide thumbs Also See for ATC32U02 iGate:
Table of Contents

Advertisement

AT C 3 2 U 0 2 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - I O M
3.0 System Confi guration
Use the System Confi guration option on the start-up screen
to adjust critical equipment settings.
The System Confi guration information will be automatically
obtained from each communicating control in the system.
Note 1: The Airfl ow Selection menu (section 3.1) will not be
present if the connected communicating control system has
no blower.
Note 2: The Pump Confi guration menu (section 3.4) will
not be present if the connected communicating control is
confi gured for No Loop Confi guration (OTHER).
Note 3: The Valve Confi guration menu (section 3.5) will
not be present if the connected communicating control is
confi gured for No Loop Confi guration (OTHER).
INSTALLER SETTINGS
THERMOSTAT CONFIG
SYSTEM CONFIG
ACCESSORY CONFIG
INPUT DEALER INFO
HUMIDITY CONFIG
TEMPERATURE CONTROL
DEMAND REDUCTION CNFG
SERVICE MODE
SETPOINT LIMITS
RESTORE DEFAULTS
DXM2
ATC32U02
SELECT OPTION
PREVIOUS
SYSTEM CONFIGURATION
AIRFLOW SELECTION
OPTION SELECTION
UNIT CONFIG
PUMP CONFIGURATION
SELECT OPTION
PREVIOUS
3.1
AIRFLOW SELECTION
Adjust the airfl ow settings for each system operating mode
using the up/down arrow buttons. Press the center button to
select each item.
• Airfl ow Settings (defaults stored in control)
• Blower Off Delay (default 60 seconds) – valid
NOTE 1: The Airfl ow Settings will only be present if the
connected communicating control is confi gured for ECM
blower.
NOTE 2: If multiple units are connected to one thermostat,
refer to section 3.6 for unit selection.
HEAT STAGE 1
HEAT STAGE 2
AUXILIARY HEAT
EMERGENCY HEAT
COOL STAGE 1
COOL STAGE 2
COOL DEHUMID 1
COOL DEHUMID 2
CONTINUOUS FAN
HEAT OFF DELAY
COOL OFF DELAY
PREVIOUS
3.3
3.2
OPTION SELECTION
C 1.0
This option allows the confi guration of heat pump options to
be modifi ed.
Adjust the Option settings using the up/down arrow buttons.
Press the center button to select each item.
• Motorized Valve (defaults stored in control) –
TE026
NOTE: "Motorized Valve" used here refers to a two-position
motorized water valve, not to be confused with the modulating
motorized water valve found in the LOOP CONFIG.
• Compressor ASCD (Anti-Short Cycle Delay
SAVE
NOTE 1: The Compressor Anti-Short Cycle Delay setting
provides equipment protection by forcing the compressor to
wait a few minutes before restarting.
NOTE 2: If multiple units are connected to one thermostat,
refer to section 3.6 for unit selection.
- valid range: obtained from control (in 25 CFM
increments)
range: 0 to 255 seconds (in 5 second increments)
AIRFLOW SELECTION
valid range: Off, On "On" delays compressor start
until the valve is fully open.
(default stored in control) – valid range: 5 to 8
(in 1 minute increments)
R e v. : 2 4 F e b . , 2 0 1 4
CFM
600
750
850
850
525
700
425
550
350
60
30
NEXT
7