Use form 69-0959 except use Table 2 and the hookup diagrams that follow.
Mode Number
(Press i key
to change)
Select
Not used
01
Fan operation
02
Not used
03
Heating cycle
04
rate
Not used
05 thru 11
Changeover
12
(T8501D only)
Not used
13
Degree
14
temperature
display
Not used
15 thru 18
Extended fan
19
operation in
a
heating
Extended fan
20
operation in
cooling
Not used
21 thru 23
Outdoor
24
temperature
display
a Mode 02 must be set to 01 to extend fan operation.
®U.S. Registered Trademark
Microelectronic Thermostat
Table 2. Thermostat installer setup options.
Factory-Setting
Display
Description
01
Heat pump and electric
heat applications where
thermostat controls fan
operation in heat mode.
03
3 cph used for
conventional systems
00
Automatic changeover
00
Temperature is
displayed in °F
01
Fan operation is
extended 90 seconds
after the call for heat
ends.
01
Fan operation is
extended 90 seconds
after the call for cool
ends
00
No outdoor temperature
is displayed
ATA11H01
INSTALLATION INSTRUCTIONS
Other Choices
(Press
or
key to change)
Display
Description
00
Conventional applications where
equipment controls fan operation
in heat mode.
01, 06,
01—1 cph used for radiant floor
or 09
heat, gravity systems
06—6 cph used for conventional
systems.
09—9 cph used for electric heat
systems
01
Manual changeover
01
Temperature is displayed in °C
00
No extended fan operation after
the call for heat ends
00
No extended fan operation after
the call for cool ends
01
Outdoor temperature is displayed.
Needs a C7089B1000 Outdoor
Sensor to operate.
T8501D1087
(continued)
69-1312-1

Advertisement

loading

Summary of Contents for ClimateMaster ATA11H01

  • Page 1 ATA11H01 Microelectronic Thermostat T8501D1087 INSTALLATION INSTRUCTIONS Use form 69-0959 except use Table 2 and the hookup diagrams that follow. Table 2. Thermostat installer setup options. Other Choices Mode Number Factory-Setting (Press key to change) (Press i key to change) Select...
  • Page 2 ATA11H01 MICROELECTRONIC THERMOSTAT Table 2. Thermostat installer setup options (continued). Other Choices Mode Number Factory-Setting (Press key to change) (Press i key to change) Select Display Description Display Description Not used 25 thru 32 — — — — Minimum off...