Page
8-4
Front Panel
Status Code
35
36
37
38
39
3A
3b
3d
3F
40
41
42
43
44
45
46
47
Searching for the User File Directory (UFD) account [1,2] on first logical of
the primary boot device.
Searching for a BADBLK.SYS file on the first logical of the primary boot
device. Valid only on disk drives that use a BADBLK.SYS file.
Loading BADBLK.SYS on the first logical of the primary boot device.
Valid only on disk drives that use a BADBLK.SYS file
Searching for account [1,4] on the first logical of the primary boot device.
An error at this point may indicate disk problems. Try reloading the latest
version of the system software.
The computer is looking for the system monitor file in [1,4] as the primary
boot device. If this file is missing, reload the latest version of the system
software.
Loading the AMOS monitor from the primary boot device. If an error
occurs at this point, try reloading the latest version of the system software.
Beginning to execute the AMOS monitor from the primary boot device. If
an error occurs at this point, try reloading the latest version of the system
software.
Bootup failed because of a time-out error. This may indicate faulty memory,
an addressing problem, or it can't find the .MON file specified in CMOS.
Bootup failed because of an invalid primary boot device selection. Access
the CMOS setup routine by pressing Reset , then pressing the
the code "C5" appears on the front panel. Verify the device and unit number
settings on the CMOS menu.
UPS inverter on. Normal operation recovering from an AC power failure.
Only displays if the UPS status cable is installed on the UPS port.
UPS is bypassed. System running without UPS battery protection. Please
turn on UPS run switch.
UPS inverter on, AC power failure detected, and the system is running off
batteries. This status is updated every second that the AC power is off.
Not valid, system dead.
UPS is on, and batteries are low. Batteries are recharging, please check.
UPS is bypassed and batteries are low.
UPS inverter is running and a low battery condition exists. Only 2 minutes
of power remaining! System shutdown is imminent.
Not valid, system dead.