F/no FL Fault Code – Burner failed to ignite or reignite
Before beginning this procedure make sure:
RV LP gas tank valve is open.
I
Refrigerator solenoid gas valve manual shutoff is open.
I
LP gas pressure at the solenoid gas valve pressure tap is 10.5.
I
Models and fault indicator displayed.
ON
GAS LED
flashing
GAS
constantly
N61X/N81X
Check burner.
Check that electrode tip-to-
burner air gap is correct.
Check spark/sense electrode
assembly for continuity.
Check gas valve solenoid
resistance.
.
Check gas valve solenoid
wires for continuity.
Check voltage across power
board terminals GV and
GV GND.
N6XX/N8XX Models
AC
LP GAS
AUTO
N62X/N82X
NO
Burner
clean?
YES
Air gap
NO
1/8 to 3/16
inch?
YES
NO
Continuity?
YES
NO
79 to 85 Ω?
YES
NO
Continuity?
YES
NO
Voltage?
YES
www.norcold.com/cda
N64X/N84X
Clean and service burner.
See page 30.
Set electrode-to-burner air gap
1/8 to 3/16 inch.
Replace spark/sense electrode
assembly.
Replace gas valve.
Replace gas valve wires.
Replace power board.
Faulty or obstructed gas valve.
Replace gas valve.
Refrigerator Service Manual