no LP - no FL Fault Code – Burner failed to ignite or reignite
Before beginning this procedure make sure:
■
RV LP gas tank valve is open.
■
Refrigerator solenoid gas valve manual shut-off is open.
■
LP gas pressure at the solenoid gas valve pressure tap is 10.5 to 11.5 in. w.c.
Fault indicator displayed:
ON
OFF
Check burner.
Check that electrode-to-
burner air gap is correct.
Check spark/sense electrode
assembly for continuity.
Check gas valve solenoid
resistance.
Check gas valve solenoid
wires for continuity.
Check voltage across power
board terminals GV and
GV_GND.
1200XX/120X-IMXX Models
Flashing "no"
Coldest
Cold
TEMP
MODE
SET
AUTO
AC
LP GAS
Blinking LP GAS LED
NO
Burner
clean?
YES
Air gap
NO
1/8 to 3/16
inch?
YES
NO
Continuity?
YES
NO
79 to 85 Ω?
YES
NO
Continuity?
YES
NO
Voltage
present?
YES
www.norcold.com/cda
on
1 COLD - 9 COLDEST
SET
TEMP
Flashing "no" and "FL"
Clean and service burner.
See page 28.
Set electrode-to-burner air gap
1/8 to 3/16 inch.
Replace spark/sense electrode
assembly.
Replace gas valve.
Replace gas valve wires.
Replace power board.
See page 40.
Faulty gas valve.
Replace gas valve.
Refrigerator Service Manual