Install and use with care. Follow all local
codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code, ANSI Z223.1/NFPA 54*. Firebox must
be electrically grounded in accordance with
the National Electrical Code, ANSI/NFPA70
(latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
OPERATION
This firebox has been tested and approved
under ANSI Z21.91 for use with any gas
log approved to ANSI Z21.11.2 for indoor
applications and ANSI Z21.97 for outdoor
applications. (Physical size limitations apply.
Refer to minimum firebox requirements sup-
plied with log heater.) It requires no outside
venting or chimney making installation easy
and inexpensive. When used without blower,
heater installed in firebox requires no electric-
ity making it ideal for emergency backup heat.
PLANNING
Plan where you will install the firebox. This will
save time and money later when you install
the firebox. Before installation, consider the
following:
1. Where firebox will be located: Allow for
wall and ceiling clearances (see Installa-
tion Clearances, page 10).
2. Everything needed to complete fireplace
installation.
4

LOCAL CODES

PRODUCT FEATURES

LOCATING FIREBOX

www.SuperiorFireplaces.US.com
State of Massachusetts: The installation
must be made by a licensed plumber or
gas fitter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
REFRACTORY BRICK LINER
Your firebox may feature a concrete refractory
brick liner. As with all concrete liners, this liner
may develop slight cracks when exposed to
heat. These cracks will not affect performance
of fireplace or vent-free gas logs.
OUTSIDE AIR KIT ACCESSORY
An optional AK4 air kit provides additional
outdoor air to improve burner efficiency and
reduce build-up of condensation in the living
space. Follow instructions included with air kit.
3. These models CANNOT be installed in
a bedroom unless maximum Btu rating
of installed vent-free log set is less than
10,000 Btu/hr.
4. Proper air for combustion and ventilation
(page 7).
126709-01A