Local Codes; Unpacking; Product Features - Superior VRT43STWS Installation And Operation Instructions Manual

Unvented (vent-free) universal firebox
Table of Contents

Advertisement

Install and use firebox with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel Gas
Code ANS Z223.1/NFPA 54*. Firebox must
be electrically grounded in accordance with
the National Electrical Code, ANS/NFPA70
(latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
1. Remove all protective packaging from
inside firebox. Carefully lift the firebox off
the bottom corrugated tray.
2. Carton should contain 2 deflective hoods
and hardware packet in addition to firebox
assembly. If items are missing, inform
dealer where you bought firebox.
3. Check firebox for any shipping damage.
If firebox is damaged call INNOVATIVE
HEARTH PRODUCTS at 1-800-655-2008
for replacement parts before returning to
dealer.
OPERATION
This firebox is designed for use with approved
ANS Z21.11.2 decorative type unvented
room appliances. (Physical size limitations
apply. Refer to minimum firebox requirements
supplied with log appliance.) It requires no
outside venting or chimney making installation
easy and inexpensive. When used without
the blower, the firebox requires no electricity
making it ideal for emergency backup heat.
4

LOCAL CODES

UNPACKING

PRODUCT FEATURES

www.SuperiorFireplaces.US.com
State of Massachusetts: The installation
must be made by a licensed plumber or
gas fitter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room appliances
shall provide to each purchaser a copy of
527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
NOTICE: The firebox identifica-
tion label (including model num-
ber, serial number, clearances,
etc.) is located underneath the
heat shield. See Figure 19, page
16.
BLOWER ACCESSORY
This firebox will accept the GA3750A ac-
cessory. The variable blower allows you to
select the fan speed you desire. The blower
circulates heated air from the firebox into the
room. Use of blower is optional.
BRICK LINER
This firebox features a concrete brick liner. As
with all concrete liners, this liner may develop
slight cracks when exposed to heat. These
cracks will not affect the performance of the
firebox or vent-free gas logs.
HEAT DEFLECTIVE HOOD
Two (2) black painted steel hoods come
standard with the unit, which must be installed
for a safe operation.
126703-01A