14. Starting the Heater for the First Time

After you have installed the heater, bleed the fuel supply system carefully.
NOTE:
As a result of the low fuel consumption the heater must be switched on several times to fill the fuel line and prime the
system.
Conduct a trial of the heater to check all the connections for leaks and to ensure that they are secure. If the heater
suffers a fault during operation, the fault must be located and remedied.

14.1 Control Element Description

Control Element
Figure 32. Control element

14.2 Ventilation Mode (Optional Connection)

Where desired, a separate switch installed between the 20 ga pink wire (X6, Pin-16) and a ground point allows the user
to chose between heating and ventilation mode. Refer to Figure 31, item S3 for connection detail. In ventilation mode
(switch S3 'On') the fan speed is regulated by the control element knob.
www.webasto.us
Rotary knob for:
- Switching on and off
- Setting the room temperature
-
Resetting after a fault cut-out
Indicator / Error code display
!
Changes to the settings
on the control element
are implemented after
a delay.
Starting the Heater for the First Time