Installer setup
Setup functions
0300
Manual/Auto
changeover
0310
Auto changeover
deadband
0320
Temperature
display
0330
Daylight savings
0340
Indoor temp.
sensor
0342
Outdoor temp.
sensor
0345
Dual fuel heat
pump control
0346
Dual fuel heat
pump upstage to
furnace timer
0350
Heat pump
compressor lockout
0360
Heat pump
auxiliary lockout
0365
Discharge temp.
sensor
0370
Indoor humidity
sensor
0372
Indoor humidifica-
tion control
0374
Humidifier fan
action
0379
Dehumidification
control
(English: Page 4 • Français: Page 10 • Español: Página 16)
Settings & Options
0 Manual (User options: Heat/Cool/Off)
1 Automatic (User options: Heat/Cool/Auto/Off)
(System selects heat/cool based on indoor temp.)
3 Heat/cool settings 3°F apart (1.5°C)
[Other options: 2-9 (2°F to 9°F/1°C to 5°C)]
0 Fahrenheit
1 Celsius
1 Auto-change to daylight savings time (through 2006,
and for areas that do not use the new 2007 DST calendar)
2 Auto-change to daylight savings time (2007 and beyond,
for areas that use the new 2007 DST calendar)
0 Daylight savings time is turned off
0 Display temp. at thermostat location only
1 Display temp. at indoor sensor location(s)
2 Average between thermostat & sensor location(s)
E Auto Discover
0 None
1 Remote sensor
1 Balance point plus 2°F droop
0 Balance point only
2 Balance point/Aux Heat Lockout plus 2°F droop
60 60 minutes
[Other options: 0, 30, 45 or 75 minutes]
0 No compressor lockout
[Other options: 5 to 60°F (-15°C to 15.5°C)]
0 No heat pump auxiliary lockout
[Other options: 5 to 65°F (-15°C to 18.5°C)]
E Auto Discover
0 No
1 Yes
1 Internal sensor in thermostat
0 Sensors disabled
2 External sensor
E Auto Discover
E Auto Discover
0 Off
1 Humidify (no frost protection)
3 Humidify (with frost protection)
0 Humidify only while fan or heat is on
1 Humidify forces fan on
2 Humidify only when heat is on
3 Humidifier operates independent of fan
0 No dehumidification control
1 Dehumidify with air conditioner
3 Whole house dehumidifier
(factory default in bold)
**
**
**
**
**
**
**