Electrical Connection - Miele DRIB XL Operating And Installation Instructions

Internal/external blower
Table of Contents

Advertisement

,WARNING
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
All electrical work should be
performed by a qualified electrician
in strict accordance with national
regulations (for USA: ANSI-NFPA
70) and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous.
Ensure that power to the appliance
is off while installation or repair work
is performed.
The blowers DRIB/DREB XL may
only be operated with Miele
DAR 1120, 1130, or DAR 1220, 1230
Range hoods.
The blowers DRIB/DREB XXL may
only be operated with Miele
DAR 1130, 1150, or DAR 1230, 1250
Range hoods.
^ Verify that the voltage, load and
circuit rating information found on the
data plate, match the household
electrical supply before installing the
blower.
If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or contact Miele's
Technical Service Department. See
back cover for contact information.

Electrical connection

WARNING:
THIS APPLIANCE MUST BE
GROUNDED
Important: To increase security
before the machine is installed, it is
recommended to install a protective
switch (30 mA).
^ Connect the blower to the cooker
hood using the connecting cable and
the 6-pole plug connector.
^ Use the extension cable supplied to
lengthen the cabling if necessary.
Maximum load
DRIB, DREB XL . . . . . . . . . . . . . . 615 W
DRIB, DREB XXL . . . . . . . . . . . . . 800 W
Voltage . . . . . . . . . . . . . . . . . . . . . 120 V
Frequency . . . . . . . . . . . . . . . . . . 60 Hz
Circuit Rating . . . . . . . . . . . . . . . . . 15 A