Test 1 120Vac Electrical Supply - Kenmore 796.8219 Series Service Manual

Electric & gas dryer
Hide thumbs Also See for 796.8219 Series:
Table of Contents

Advertisement

Test 1
120V AC Electrical supply
NOTE: To properly check power supply in case of floating neutral or
high resistance connections, a load must be applied to the
circuit. It is important that the power button be pressed while
checking the voltages as described below.
BL2
With the dryer plugged in, press the
POWER button to turn on dryer.
Check the voltage at the main PCB
between BL2-1 (WH) and the black
wire on the black tab relay. Is 120
VAC present while pressing the start
button?
(NOTE: For gas dryers skip this step.)
With the dryer plugged in, check the
voltage at the terminal block between the
neutral (WH) and L1 (BK) terminals. Is
the voltage 120 VAC while pressing the
START/PAUSE button?
With the dryer plugged in, check the
voltage at the power cord plug
between the neutral and L1 (and L2
for electric dryers). Is the voltage 120
VAC while pressing the
START/PAUSE button?
Replace the power cord.
YES
NO
YES
YES
19
•Replace
main PCB.
•Replace
YES
display
PCB.
•Check
power cord.
•Check
terminal
block
NO
connection
s.
•Check the
power
supply fuse
or circuit
breaker.
NO
•Check the
receptacle
connections.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

796.9219 series796.9102 series796.8102 series

Table of Contents