Installing and Connecting the Drain Hose of the Indoor Unit

When installing the drain hose for the indoor unit, check if condensation draining is adequate.
When passing the drain hose through the 65-mm hole drilled in the wall, check the following:
The hose must
NOT slant upwards.
Shield
Drain hose
Extension drain hose
12
E-
08'FORTE_VIVACE_Inv_IM_28492A£¨4£©_E.indd 12
The end of the drain
Do NOT bend the hose
in different directions.
hose must NOT be
placed under water.
Drain hose installation:
1
If necessary, connect the 2-meter extension drain hose to the drain hose.
2
If you use the extension drain hose, insulate the inside of the extension drain
hose with a shield.
3
Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain
hose tightly with a clamp.
 If you don't use the other drain hose hole, block it with a rubber stopper.
4
Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.
5
Pass the drain hose through the hole in the wall. Check if it slants downwards
as seen in the picture.
 The hose will be fixed permanently into position after finishing
the installation and the gas leak test; refer to page 17 for further details.
 DO NOT WALL UP THE DRAIN HOSE CONNECTION !
Drain hose connection must be easy accessible and serviceable
5cm
less
Do NOT place the end
Keep a clearance of at
least 5cm between the
of the drain hose in a
hollow.
end of the hose and
the ground.