Samsung SCX-6555N Service Manual page 176

Digital laser mfp
Hide thumbs Also See for SCX-6555N:
Table of Contents

Advertisement

Code
Displayed Name
08-800
Bypass Feed Clutch
08-810
T1 Pick-Up Clutch
08-820
T2 Pick-Up Clutch
08-830
T3 Pick-Up Clutch
08-840
T4 Pick-Up Clutch
08-850
Registration Clutch
08-860
Duplex Feed Clutch
08-870
Duplex Gate Clutch
08-920
T2 Feed Motor Run
08-930
T3 Feed Motor Run
08-940
T4 Feed Motor Run
7) Developer
Code
Displayed Name
09-100
MHV Bias
09-110
MHV Bias Read
09-200
Dev Bias
09-300
THV(+) Bias
09-310
THV Bias Read
09-400
THV(-)Bias
09-500
SMPS Fan Run
09-510
SMPS Fan Run Ready
09-600
Toner Dispense Motor
09-700
Toner Sensor
09-800
Detach Bias
8) Fuser
Code
Displayed Name
10-100
Fuser Power On
10-200
Fuser Temperature A
10-210
Fuser Temperature B
10-300
Fuser Unit Fault
10-400
Fuser Motor Forward
10-500
Fuser Fan Run
10-600
Fuser Bias
Service Manual
CÓPIA NÃO CONTROLADA
Alignment & Troubleshooting
Meaning
Engages drive to pick up a paper from bypass.
Engages drive to pick up a paper from tray1.
Engages drive to pick up a paper from tray2. (Optional)
Engages drive to pick up a paper from tray3. (Optional)
Engages drive to pick up a paper from tray4. (Optional)
Engages drive to registartion rolls.
Engages drive to feed a paper into duplex path.
Engages drive to ready a paper into duplex path.
T2 Feed Motor On/Off
T3 Feed Motor On/Off
T4 Feed Motor On/Off
Meaning
MHV bias voltage on at normal drive level
Detect what the MHV value is on the MHV Roller
Dev bias voltage on at normal drive level
THV plus bias voltage on at normal drive level
Detect what the THV value is on the THV Roller
THV minus bias voltage on at normal drive level
Start/Stop Deve. Fan run
Detects if Deve Fan runs at normal speed.
Toner Dispense Motor On/Off
TC sensor in developer tank.
Detach bias voltage on at normal drive level
Meaning
It controls temperature of fuser as 180 degrees.
Detects what the temperature A is on fuser.
Detects what the temperature B is on fuser.
Detects if the IH board for controling fuser is normal.
Fuser Motor Forward On/Off
Start/Stop Fuser Fan run
Fuser bias voltage on at normal drive level
4-76
CÓPIA NÃO CONTROLADA
State
Displayed
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
State
Displayed
On[Off]
Numeric 3 digits
On[Off]
On[Off]
Numeric 3 digits
On[Off]
On[Off]
High[Low]
On[Off]
Numeric 3 digits
On[Off]
State
Displayed
On[Off]
Numeric 3 digits
Numeric 3 digits
Normal/Fault
On[Off]
On[Off]
On[Off]
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scx-6555xaz

Table of Contents