4 SERVICE

4.6 ADJUSTMENT PROCEDURE

4.6.1
ADJUSTMENTS OF INTERFACE UNIT MODULE 6/600
ADJUSTMENT AND CONTROL OF VOLTAGE REGULATORS.
1.
Switch on the set.
2.
Select channel 28.
3.
Check 13.2V with a multi-meter on fuse F1-6 and P3-6 pin 9.
4.
Check 5V +0.2V with a multi-meter on U1-6 pin 3.
5.
Connect the multi-meter to Q9-6's collector and adjust the 10V regulator with R65-6 to 10V +0.2V.
6.
Connect the multi-meter to Q11-6's collector and key the transmitter.
7.
Adjust the PA-regulator with R68-6 to 8.4V + 0.2V.
8.
Connect the multi-meter to R6-6.
9.
Adjust RX-control voltage (VD
ADJUSTMENT OF SELCALL TEST TONE
The procedure is described in the manual, INSTRUCTIONS FOR IDENTITY AND
SERVICE PROGRAMMING OF VHF RT2047, section 3.8: SELCALL TEST TONE
4.6.2
ADJUSTMENTS OF RX-SYNTHESIZER MODULE 200
1.
Select channel 28.
2.
Check the DC-control voltage on R217 with a multi meter to be 8V + 0.4V. If components have been
changed in the VCO-circuit, it is possible that the jump wire used for adjusting the VCO frequency
range has to be moved until the 8 + 0.4 V is achieved.
3.
Control the frequency F
ADJUSTMENT OF F
1.
Connect "calibrated" test probe to soldering point for F
2.
Adjust L202 until the core is 0.5 mm over the coil form and potentiometer R209 CCW to 1/3 of the
range.
3.
Adjust L206 to Max. deflection on the Tp meter.
4.
Select channel 6.
5.
Check the deflection on the Tp meter to be nearly the same as ch. 28. Otherwise obtain the level
on ch. 6 and ch. 28 to be nearly the same by adjusting L206.
6.
Connect test probe to soldering point for F
7.
Adjust L202 to Max. deflection on the Tp meter and secure that deflection on ch. 6 and ch. 28 are
nearly the same.
The levels measured with power meter (mW) and 50
F
to TX: 0.25 mW
L01
F
to RX: 5 mW +1.5 dB.
L01
4.6.3
ADJUSTMENTS OF TX-EXCITER MODULE 300
1.
Select channel 28.
2.
Connect frequency counter to the top of T306.
3.
Adjust trimming capacitor C331 until the frequency counter shows 21MHz + 20Hz. Note that when
the transmitter is keyed you can measure on R332 and adjust R331 until the frequency counter
show 157400000 Hz + 150 hz.
4.
Check the clock frequency on microprocessor to be 2.1 MHz on FP301 .
5.
Check the DC-control voltage on R344 to be 8 + 0.4V. If components have been changed in the
VCO-circuit it is possible that the jump wire used for adjusting the VCO frequency range has to be
moved until the 8 + 0.4V is achieved. (With the Transmitter Keyed)
9545
) to 8V + 0.2V with R16-6.
RX
to RX with a frequency counter to be 140.600 MHz.
L01
TO TX AND F
TO RX.
L01
L01
to TX.
L01
to RX.
L01
impedance must be: