96% two stage multi-position residental gas furnaces (33” tall)

Advertisement

Quick Links

NOTES:
1.
If the furnace is equipped with NOx screens and is to be
used with LP (propane) gas, the screens must be removed
prior to start-up.
2.
Drip leg in the gas line must be installed.
3.
The furnace controls require correct polarity on the power
supply and a proper ground.
4.
Y & G must be connected to the control board for cooling
operation.
5.
External filters are required on all configurations.
6.
Electrical or gas entry is available on both casing sides.
Airflow CFM (Bottom Return without Filters)
Models
0.5" ESP (Nominal)
*D-A**
*C-A**
TM9V060B12MP11
600
690
TM9V080B12MP11
600
680
TM9V080C16MP11
850
905
TM9V100C16MP11
870
910
TM9V100C20MP11
960
1155
TM9V120D20MP11
960
1160
Input
Total Unit
Rate
Models
Max
Min
TM9V060B12MP11
60,000
21,000
TM9V080B12MP11
80,000
28,000
TM9V080C16MP11
80,000
28,000
TM9V100C16MP11
100,000
35,000
TM9V100C20MP11
100,000
35,000
TM9V120D20MP11
120,000
42,000
Other airflows are available. see Tech Guide for all CFM options.
* Cool Tap.
** Adjustment Tap.
LED INDICATOR
Slow Green Flash - Normal operation in standby mode.
Slow Amber Flash - Normal operation with call for cooling.
Two Amber Flashes - Normal operation with call for heat.
Three Amber Flashes - Normal operation, burner is on at end of
thermostat cycle.
Six Amber Flashes - Normal operation with call for heat pump
heating.
Any Red Flash - Fault condition. NOTE: 4 or 5 flashes may indi-
cate a blown fuse on the circuit board.
Subject to change without notice. Printed in U.S.A.
Copyright © 2009 by Johnson Controls, Inc. All rights reserved.
Johnson Controls Unitary Products
Norman, OK 73069
7.
To measure total static pressure, add supply duct pressure
to the return duct pressure, add pressure drop across the 'A'
coil, and add pressure drop across the filter. Ignore negative
signs on the readings.
8.
Inlet gas pressure should be 7" w.c. for natural gas and 11"
w.c. for propane. Nominal manifold gas pressure is 3.5" w.c.
for natural gas and 10" w.c. for propane at max. input.
9.
For downflow application the vent blower must be rotated 90
left or right as shown.
Minimum Wire
Size awg @ 75'
One-Way
*B-A**
*A-B**
1000
1305
14
1000
1290
14
1175
1670
14
1160
1655
14
1605
2215
12
1595
2180
12
Time For 1 ft
Air Temp. Rise
Air Temp. Rise
(1030 Btu/Ft
Amps
Max Input °F
Min Input °F
(On Max. Rate)
9
35 - 65
35 - 65
9
35 - 65
30 - 60
12
35 - 65
35 - 65
12
35 - 65
30 - 60
14
35 - 65
35 - 65
14
35 - 65
35 - 65
*438336*
438336-URG-A-0209
Supersedes: Nothing
5005 York Drive
This document does not replace the installation instructions, which must be referred to for
detailed information.
SUPPLY END
.56"
Combustion
B
Air Inlet
.56"
.56"
20"
Maximum
Over Current
Combustion Air Inlet
Protection
15
Condensate Drain
(Downflow)
15
Vent Connection
15
Outlet
15
20
20
3
Natural Gas
3
) Seconds
62
46
46
37
LEFT SIDE
37
Follow all national and local codes and standards in addition to this document.
31
The installation must comply with regulations of the serving gas supplier, local building,
heating, plumbing, and other codes. In absence of local codes, the installation must comply
with national codes and all authorities having jurisdiction.
CLEARANCES
Application
Top
Vent
Rear
Side
Front*
Floor
Combustible
Closet
Line Contact
1. For combustible floors only when used with special
sub-base.
* 24" clearance in front and 18" on side recommended for
service access.
All furnaces approved for alcove and attic installation.
QUICK REFERENCE GUIDE
96%TWO STAGE MULTI-POSITION RESIDENTAL
GAS FURNACES (33" TALL)
RETURN END
2" Diameter
3"
Vent Connection
23.8"
Outlet
24.25"
Combustion Air Inlet
Gas Pipe
Condensate Drain
Entry
(Downflow)
Electrical
Entry
Vent Connection
Outlet
Condensate
Drain
23"
Thermostat
Wiring
Optional Return Air
Cutout (Either side)
28.5"
29.5"
RIGHT SIDE
DIMENSIONS
Upflow
Downflow
Horizontal
1"
0"
0"
All 'B' Cabinet Furnaces
0"
0"
0"
All 'C' Cabinet Furnaces
0"
0"
0"
All 'D' Cabinet Furnaces
0"
0"
1"
0"
0"
0"
1
Combustible
Combustible
Yes
Yes
Yes
No
No
Yes
DURING INSTALLATION,
DOORS MUST REMAIN ON
FURNACE WHEN MOVING
B
OR LIFTING.
Clips can be flipped
into the up position
for coil cabinet or
plenum attachment
A-COIL
14"
1"
33"
1.5"
A
FRONT
Cabinet Size
A (in)
B (in)
17-1/2"
16-3/8"
21"
19-7/8"
24-1/2"
23-3/8"

Advertisement

loading

Summary of Contents for Johnson Controls TM9V060B12MP11

  • Page 1 Any Red Flash - Fault condition. NOTE: 4 or 5 flashes may indi- cate a blown fuse on the circuit board. Subject to change without notice. Printed in U.S.A. *438336* Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 This document does not replace the installation instructions, which must be referred to for detailed information.
  • Page 2 MOST COMMON INSTALLATION CONFIGURATIONS (MORE OPTIONS AVAILABLE MULTI-POSITION CONFIGURATION INFORMATION: Ensure that all PVC venting has at least 1/4” per foot slope towards the furnace. Furnace is multi-position and may be installed in any of the configurations shown. The furnace condensate pan is self priming and contains an internal trap.

This manual is also suitable for:

Tm9v080c16mp11Tm9v080b12mp11Tm9v100c16mp11Tm9v100c20mp11Tm9v120d20mp11