Certifications and Compliances
Safety
Input rating
Over voltage category
General Specifications
Characteristics
Display
Display Count
Over range Indication
Sampling Rate
Operating
Relative Humidity
Storage Environment:
Power source:
Battery Life:
Low Battery Indicator:
Auto power off
Dimensions
Maximum Cable Size
Weight:
RANGES and ACCURACY SPECIFICATION
Accuracy: Accuracy specifications at 23°C ±5°C (73.4°F ±9°F) less than 75% RH.
Temperature Coefficient: 0.1 times the applicable accuracy specification per degree C
from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F)
Electrical Specification: Accuracy are ±(reading plus number of digits) at 23°C ±5°C
(73.4°F ±9°F) <75% RH
Form number TM61764-6-8
Designed to EN 61010-1, EN 61010-2-032, UL 61010B-1,
UL 61010B-2-032 specifications
1000V DC Category III
600V DC Category IV
750V AC Category III
600V AC Category IV
CAT IV: Outside and service entrance.
CAT III: Distribution level mains, fixed installation.
CAT II: Local level mains, appliances, and portable equipment.
CAT I: Signal level, special equipment or parts of
equipment, telecommunication, electronics.
Description
3¾ Digit LCD display
6600 count, maximum reading 6600
"OL" is displayed
2.0 time/second
0°C to 50°C (32°F to 122°F)
0 ~ 70% RH
-20°C to 60°C (-4°F to 140°F) at <80% relative humidity
9V Battery (NEDA 1604)
200 hours typical (alkaline) {61-764}
200 hours typical (alkaline) {61-766}
150 hours typical (alkaline) {61-768}
symbol indicates low battery voltage
Approximately 30 minutes
8.7" H X 3.1 " W X 1.8 " D
222mm H X 80mm W X 45.5mm D
ACA 1¼" (36mm)
Approximately 12.4 oz. or 350g including battery
Rev 5 November 2007