IDEAL 61-764 Instruction Manual

IDEAL 61-764 Instruction Manual

600a clamp meters w/tightsight display
Hide thumbs Also See for 61-764:

Advertisement

600A Clamp Meters
w/TightSight™ Display
Instruction Manual
TightSight™ Display
CAT.IV 600V
CAT.III 1000V
V
61-766
V
Hz
MAX
40
MIN
A
600
PEAK
True RMS
0
10
20
30
V/Ω
COM
CAT.IV 600V
CAT.III 1000V
MAX
1000V
750V
600A
HOLD
OFF
40
600
V
#61-764
#61-766
#61-768

Advertisement

Table of Contents
loading

Summary of Contents for IDEAL 61-764

  • Page 1 #61-764 #61-766 #61-768 600A Clamp Meters w/TightSight™ Display Instruction Manual CAT.IV 600V 600A CAT.III 1000V HOLD 61-766 Ω PEAK True RMS V/Ω CAT.IV 600V CAT.III 1000V 1000V 750V TightSight™ Display...
  • Page 2: Read First: Safety Information

    Read First: Safety Information Understand and follow operating instructions carefully. Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired. WARNING To avoid possible electric shock, personal injury or death, follow these guidelines: •...
  • Page 3 • Bright, bold backlight • Cat IV-600V/Cat III-1000V • 61-764 model is averaging sensing, rms calibrated • 61-766 model is true rms sensing, measures capacitance, frequency and lower currents with a 40 AAC range for troubleshooting motors and adjustable speed drives •...
  • Page 4: Main Display

    Main Display Main Display Icons 15. 4000 count display 16. AC measurement 17. DC measurement APO HOLD MAX MIN P + P - 18. Polarity indicator for DC 19. Range ( ) nmµF 20. Auto Power Off (APO) kMΩ 21. Data Hold 22.
  • Page 5 OPERATION: High Voltage Warning (HI-V) The meter indicates when 30V AC/DC voltage is present by lighting the red LED and beeping. This voltage warning works on all functions and ranges for enhanced safety. So, even if the meter is set on the wrong function, the meter alerts the user that dangerous voltage is present. Auto/Manual Ranging Mode ( The meter defaults to autoranging mode when powered on.
  • Page 6 Selectable Auto Power Off (APO) Feature The meter automatically powers itself down after about 30 minutes of no use. Press any button, and the meter will wake up and display the last reading taken before power down. This feature can be overridden by holding the Range ( ) button while turning the function switch from Off to any other position.
  • Page 7: Measuring Voltage

    Measuring Voltage: AC Voltage DC Voltage Measuring Resistance (Ohms): • Verify the circuit is de-energized to obtain accurate measurements. Page 7...
  • Page 8 Verifying Continuity ( • Verify the circuit is de-energized. • The meter will sense the level of resistance and beep if the resistance is less than 35 Ω to confirm that continuity is present. Closed Open Circuit Circuit Capacitance (61-766): Page 8...
  • Page 9: Battery Replacement

    • Clean the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Service and Replacement Parts: This unit has no user-serviceable parts. For replacement parts or to inquire about service information contact IDEAL INDUSTRIES, INC. at 1-877-201-9005 or visit our website www.testersandmeters.com. Page 9...
  • Page 10: Specifications

    Samples 2 times per second, nominal. Auto Power Off: Approximately after 30 minutes of non-use. Battery Life: 400 hours continuous with Alkaline (61-764) 200 hours continuous with Alkaline (61-766) 150 hours continuous with Alkaline (61-768) Low Battery Indication: The "...
  • Page 11 Ranges & Accuracies: AC Converter: 61-764 model is averaging sensing, rms calibrated 61-766, 61-768 models are true rms sensing. Accuracy: Accuracy is specified as +/-(a percentage of the reading + a fixed amount) at 23°C±5°C (73.4°F ± 9°F), less than 75% relative humidity.
  • Page 12: Warranty Statement

    Any implied warranties arising out of the sale of an IDEAL product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above.