Input (Btu/Hr)*
IBR Heat Capacity (Btu/Hr)
Valve Capacity (Lbs/Hr)
Max Water Pressure (Psi)
Burner Model
Fuel Type
Orifice Size
Fuel Input Rate (Cfm)
Max. Inlet Pressure ("W.C.)
Min. Inlet Pressure ("W.C.)
Manifold Pressure ("W.C.)
Head Position
Air Shutter
Draft Over Fire ("W.C.)
Draft in Stack ("W.C.)
CO
Reading
2
AFUE
EMG-31 120
EMG-31 140
120,000
88,000
160
30
Carlin EZ-Gas
Carlin EZ-Gas
Nat.
L.P.
Nat.
Gas
Gas
Gas
0.242"
11/64
0.250"
1.95
0.79
2.28
11"
11"
11"
5"
5"
5"
3.5"
3.5"
3.5"
Factory
Factory
Factory
Set
Set
Set
31%
30%
45%
-0.02"
-0.02"
-0.010"
-0.02"
-0.02"
-0.02"
9.0%
11.0%
9.0%
83.8%
83.8%
83.0%
EMG-31 160
140,000
160,000
101,000
114,000
160
160
30
30
Carlin EZ-Gas
L.P.
Nat.
Gas
Gas
13/64
0.290"
0.95
2.60
11"
11"
5"
5"
3.5"
3.5"
Factory
Factory
Set
Set
42%
65%
-0.02"
-0.005"
-0.015"
-0.02"
11.0%
9.0%
83.0%
82.2%
L.P.
Gas
7/32
1.06
11"
5"
3.5"
Factory
Set
78%
-0.005"
-0.02"
11.0%
82.2%