IVT AY-XP12FR-N Service Manual page 24

Split type room air conditioner
Hide thumbs Also See for AY-XP12FR-N:
Table of Contents

Advertisement

AYXP12FRN
Item
Mode
Heat exchanger
Cooling
thermistor (TH2)
Dehumidifying
Heating
2. Outdoor unit
Item
Mode
Compressor
Cooling
chamber ther-
Dehumidifying
mistor (TH1)
Heating
Heat exchanger
Cooling
thermistor (TH2)
Dehumidifying
Heating
Outside air tem-
Auto
perature ther-
mistor (TH3)
Cooling
Dehumidifying
Heating
Suction pipe ther-
Cooling
mistor (TH4)
Dehumidifying
Heating
Control opera-
When resis-
tion
tance is low
(temperature
judged higher
than actual)
Freeze preven-
Indoor unit evap-
tion
orator may
freeze.
Cold air preven-
Cold air preven-
tion
tion deactivates
too soon and cold
air discharges.
Control opera-
When resis-
tion
tance is low
(temperature
judged higher
than actual)
Expansion valve
Compressor
control and com-
operates, but
pressor protection
room does not
become cool or
warm (expansion
valve is open).
Outdoor unit heat
Compressor
exchanger over-
operates at low
heat prevention
speed or stops.
Expansion valve
Defrosting opera-
control
tion is not acti-
Defrosting
vated as needed,
and frost accumu-
lates on outdoor
unit (expansion
valve is closed).
Operation mode
Cooling mode is
judgment
activated even if
room tempera-
ture is low.
Operation not
Normal operation.
affected
Rating control
Defrosting opera-
Defrosting
tion is activated
unnecessarily.
Expansion valve
Compressor
control
operates, but
room does not
become cool
(expansion valve
is open).
Expansion valve
Compressor
control
operates, but
room does not
become warm
(expansion valve
is open).
3 – 4
Short-circuit
When resis-
tance is high
(temperature
judged lower
than actual)
Indoor unit evap-
Compressor
orator may
stops occasion-
freeze.
ally.
Compressor
Cold air preven-
operates at low
tion deactivates
speed or stops,
too slow.
and frequency
does not
increase.
Short-circuit
When resis-
tance is high
(temperature
judged lower
than actual)
Compressor high
Layer short-cir-
temperature error
cuit or open-cir-
indication.
cuit may result in
compressor in
normal operation.
Outdoor unit ther-
Normal operation.
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
Defrosting opera-
mistor short-cir-
tion is activated
cuit error
unnecessarily,
indication.
and room does
not become warm
(expansion valve
is open).
Outdoor unit ther-
Heating mode is
mistor short-cir-
activated even if
cuit error
room tempera-
indication.
ture is high.
Outdoor unit ther-
Normal operation.
mistor short-cir-
cuit error
indication.
Outdoor unit ther-
Defrosting opera-
mistor short-cir-
tion is not acti-
cuit error
vated, and frost
indication.
accumulates on
outdoor unit.
Outdoor unit ther-
Frost accumu-
mistor short-cir-
lates on evapora-
cuit error
tor inlet section,
indication.
and room does
not become cool
(expansion valve
is closed).
Outdoor unit ther-
Frost accumu-
mistor short-cir-
lates on expan-
cuit error
sion valve outlet
indication.
section, and room
does not become
warm (expansion
valve is closed).
Open-circuit
Compressor does
not operate.
Cold air preven-
tion does not
deactivate, and
indoor unit fan
does not rotate.
Open-circuit
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.