Download Print this page
Control 4 C4-SW120277 Series Installation Manual

Control 4 C4-SW120277 Series Installation Manual

Advertisement

Quick Links

Supported Model
C4-SW120277 Switch
Introduction
The Control4® Switch operates independently or as part of a Control4 home
automation system. It installs in a standard back box using typical wiring standards
and communicates to the Control4 system using a wireless connection.

Box Contents

Switch
Wire Nuts
Warranty Card
(this document)
Specifications and Supported Load Types
The specifications are described below.
Model Number
Power Requirements
Power Consumption
Load Types and Ratings
Supported Load Types
Maximum Load
Operational Temperature
Humidity
Storage
Control Communications
Wallbox Volume
Weight
Shipping Weight
Switch
Installation Guide
C4-SW120277-xx
120-277VAC +/-10%, 50/60Hz
This device requires a neutral connection. See
the "Sample Wiring Configurations" later in this
guide.
120V: 400mW
277: 1150mW
Incandescent, Halogen, Electronic (Solid
State) Low Voltage (ELV) transformers,
Magnetic (Iron Core, Inductive) Low Voltage
(MLV) transformers, Fluorescents, Compact
Fluorescents, LEDs, Motors
120V: 15A, 1/2HP
277V: 8A, 1/2HP
Environmental
32˚ F - 104˚ F (0˚ C - 40˚ C)
5% to 95% non-condensing
-4˚ F - 158˚ F (-20˚ C - 70˚ C)
Miscellaneous
ZigBee, IEEE 802.15.4, 2.4 GHz, 15-channel
spread spectrum radio
5.75 cubic inches
0.12 lb (0.05 kg)
0.18 lb (0.08 kg)
Warnings and Considerations
WARNING!
Turn OFF electrical power before installing or servicing this
product. Improper use or installation can cause SERIOUS INJURY, DEATH
or LOSS/DAMAGE OF PROPERTY.
ATTENTION!
Coupez l'alimentation électrique avant d'installer ou de
réparer ce produit. Une mauvaise installation ou utilisation peut entraîner
des blessures graves, décès ou perte / dommages à la propriété.
WARNING!
This device must be protected by a circuit breaker (20A max).
Cet appareil doit être protégé par un disjoncteur (20A max.)
ATTENTION!
WARNING!
Ground this device in accordance with the National Electric
Code (NEC) requirements. DO NOT rely solely upon the yoke plate's
contact with a metal back box for adequate grounding. Use the device's
ground wire to make a secure connection to the safety ground of the
electrical system.
ATTENTION!
Cet appareil doit être en conformité avec le Code national
de l'électricité (NEC). Ne comptez pas uniquement au contact de la
plaque avant avec un boîtier mural métallique pour la mise à la terre
adéquate. Utilisez cet appareil à la terre de l'appareil pour établir une
connexion sécurisée au système électrique.
IMPORTANT!
This device must be installed by a licensed electrician in
accordance with all national and local electrical codes.
IMPORTANT!
If you are unsure about any part of these instructions,
consult a qualified electrician.
IMPORTANT!
Use this device only with copper or copper-clad wire. Do
not use aluminum wiring. This product has not been approved for use with
aluminum wiring.
IMPORTANT!
Using this product in a manner other than outlined in this
document voids your warranty. Further, Control4 is NOT liable for any
damage incurred with the misuse of this product. See "Troubleshooting."
IMPORTANT!
Do NOT use a power screwdriver to install this device. If you
do, you may overtighten the screws and strip them. Also, overtightening
the screws may interfere with proper button operation.
IMPORTANT!
This is an electronic device with intricate components.
Handle and install with care!

Installation Instructions

1
Ensure that the location and intended use meet the following criteria:
Do not exceed the load capacity requirements of the switch. Refer to the load
ratings in the specifications above for details.
Install in accordance with all national and local electrical codes.
The range and performance of the wireless control system is highly
dependent on the following: (1) distance between devices; (2) layout of the
home; (3) walls separating devices; and (4) electrical equipment located near
devices.
2
Turn off the local electrical power by either switching off the circuit breaker or
removing the fuse from the fuse box. To ensure the wires do NOT have power
running to them, use an inductive voltage detector.
The back box wiring shown in this document is an example. Your
NOTE:
wire colors and functions may differ. If you are not sure which wires
are the Hot, Neutral, Load, Traveler, and Ground wires, have a trained
electrician perform the installation.
3
Prepare each wire. Wire insulation should be stripped back 5/8 of an inch
from the wire end (see Figure 1).

Advertisement

loading

Summary of Contents for Control 4 C4-SW120277 Series

  • Page 1: Box Contents

    Cet appareil doit être en conformité avec le Code national de l’électricité (NEC). Ne comptez pas uniquement au contact de la The Control4® Switch operates independently or as part of a Control4 home plaque avant avec un boîtier mural métallique pour la mise à la terre automation system.
  • Page 2: Troubleshooting

    Operation and Configuration On initial power up, all status LEDs on the switch will illuminate green indicating that the device has power. To set up this switch for use with a Control4 system, refer to the Composer Pro User Guide.
  • Page 3 ™ Sample Wiring Configurations Figure 3. Single Device Location Figure 4. Multiple Device Location Using Auxiliary Keypad Figure 5. Multiple Device Location Using Configurable Keypad...
  • Page 4 Copyright ©2013 Control4. . All rights reserved. Control4, the Control4 logo, the Control4 iQ logo and the Control4 certified logo are registered trademarks or trademarks of Control4 Corporation in the United States and/or other countries. All other names and brands may be claimed as the property of their respective owners Pricing and specifications are subject to change without notice...