Your E.P.A Flame stove's performance will be optimised if it is installed with a chimney (flue)
system that provides an adequate draft. The draft is the force that moves air from the appliance up
through the chimney and is predominantly affected by the height and diameter of the chimney, as
well as the stack temperatures of the stove. If you test the draft using a pressure gauge, the reading
should be between .05 - .07 inches of water column (w.c.) at a medium-high fire. A draft measure of
less than .03" w.c. will cause operational difficulties while too much draft (greater than .10" w.c.)
will result in over-firing of the stove. This can result in excessive operating temperatures. In this
case, the installation of elbows totaliing no more than 180° (ex.: 2 x 30° elbows, 2 x 45° elbows or 2
x 90° elbows) can be installed to help reduce excessive draft. If the addition of elbows is not
sufficient, a manual damper can be installed in the vertical flue pipe.
2.5

OUTSIDE COMBUSTION AIR

It is recommended to install 3'' (76mm) outside air intake in the room where the stove is located or
nearby (this option is not available for the XVR and XLT series).
The following are signs that a fresh air kit may be required:
 Your stove does not draw steadily, smoke rollouts occur, wood burns poorly, or back-draft
occurs whether or not there is combustion present.
 Existing fuel-fired equipment in the house, such as fireplaces or other heating appliances,
smell, do not operate properly, suffer smoke rollouts when opened, or back-draft occurs
whether or not there is combustion present.
 Opening a window slightly on a calm (windless) day alleviates any of the above symptoms.
 The house is equipped with a well-sealed vapour barrier and tight fitting windows and/or has
any powered devices that exhaust house air.
 There is excessive condensation on windows in the winter.
 A ventilation system is installed in the house.
WARNINGS for use in MOBILE HOMES (XTD 1.1 model):
DO NOT INSTALL IN BEDROOM
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR
.
MAINTAINED
THE STOVE MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME
INSTALL IN ACCORDANCE WITH
USE A FACTORY BUILT CHIMNEY THAT COMPLY WITH
THEREFORE IT MUST BE A
.
24
,
3280 (
CFR
PART
T
HT (2100 °F).
YPE
,
,
WALL
AND CEILING
).
HUD
UL 103
ULC S629
OR
/
ROOF MUST BE
.
STANDARDS
30
;

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents