How To Clean The Solution Line - Clarke Encore S20 Operator's Manual

Clarke encore s20/l20 operator's manual
Hide thumbs Also See for Encore S20:
Table of Contents

Advertisement

MAINTENANCE
Adjusting Squeegee Blades:
When properly installed the front blade should be ap-
proximately .06 above the rear blade. See figure 12.
Adjusting Squeegee Support Wheels:
The support wheels should be set at .12 above the floor
with the rear blade touching the floor. See figure 12.
WARNING: Maintenance and repairs
must be done by authorized
personnel only .
WARNING: Electrical repairs must be
done by authorized
personnel only.
Consult your Clarke Technology Authorized Service
Person to do the service procedures.
Use only genuine Clarke Technology parts.

How to Clean the Solution Line

If the solution line becomes clogged, follow this
procedure:
1. Turn key switch "OFF" and remove the key.
2. Open brush motor cover and remove brush housing.
3. Remove brushes/pads.
4. Locate the solution shut-off valve. It is located behind
the left wheel.
5. Turn solution valve "OFF". See figure 14 (A).
6. Locate the solution filter screen. It is located on the
back of the solution valve. See figure 14 (B).
7. Unscrew the female garden hose connector from the
back of the solution valve. The filter screen is in the
female connector.
8. Remove the filter screen. See figure 14 (B).
9. Clean and replace screen.
10. Attach the female garden hose connector to the
solution valve.
11. Turn solution valve to "ON".
Page -24-
REAR BLADE
CLARKE TECHNOLOGY Operator's Manual -Encore S20/L20
.06
Figure 12
Figure 13
Figure 14