Wyrestorm Enado ENA-001-010 Instruction Manual

Wyrestorm enado user interface central controller
Hide thumbs Also See for Enado ENA-001-010:

Advertisement

Part Number
ENA-001-010
WyreStorm Enado User Interface Central Controller
Instruction Manual
Thank you for choosing this WyreStorm product.
Please read these instructions carefully before installing to avoid complications later.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Enado ENA-001-010 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wyrestorm Enado ENA-001-010

  • Page 1 Part Number ENA-001-010 WyreStorm Enado User Interface Central Controller Instruction Manual Thank you for choosing this WyreStorm product. Please read these instructions carefully before installing to avoid complications later.
  • Page 2: Table Of Contents

    Contents 1. Introduction Introduction WyreStorm Enado redefines integrators’ ability to control AV distribution systems by combining powerful hardware Features and intuitive, cross-platform software to create an end-to- end AV distribution and control system that is always on, Safety Precautions updated and accessible.
  • Page 3: Package Contents

    4. Package Contents • Sleek, 1U design allows for installation flexibility in a rack, cabinet or on a shelf. • 1 x ENA-001-010 WyreStorm Enado controller • Instantaneous, intuitive control from a smartphone, • 1 x Printed product manual (also downloadable at tablet, TV, PC or MAC browser.
  • Page 4: Panel Description

    6. Panel Description i. Front Panel Description IR Blaster – IR TX IR IN – IR RX receiver input LED Power Indicator – lit when powered IR Blaster – IR TX (as 1) LED Work Indicator – lit when working (set by software) Power switch –...
  • Page 5: Typical Application

    IR Link cables are used to connect the with the source components and WyreStorm MX-0808- matrix TX to Enado. The RS232 lead should be a cross PP Matrix. Bi-directional IR is fed to and from the zones over or null-modem whilst the LAN cable should be via HDBaseT so that local IR remotes can be used for the straight through.
  • Page 6: Connection

    8. Connection Enado Controller to the IR RX ports of the matrix using the Attention: Do not connect the Enado Controller to the supplied mono IR Link cables to enable control of output mains until you have made all the following devices in display zones.
  • Page 7 Full control of connected sources and displays through the Enado central controller from any global location via the multi-platform, browser-based Enado User Interface used in conjunction with any internet-enabled device. Technical Support: support@wyrestorm.com US: +866 677 0053 EU: +44 (0) 1793 230 343...
  • Page 8: Basic Operation

    5 inch/12.7cm. This is designed for viewing in landscape orientation only. If you do not know the IP address of the Enado Controller, • The 'Compact UI', suitable for use on smartphones, log in to the router and check the connected devices IP small browsing devices/media players, etc.
  • Page 9: Enado Live Ui Elements

    8. Date & Time display - calculated from the display device PC, Mac & Linux web browser links to the Enado interface should be saved as standard bookmarks or 9. Room/Zone Global controls - present in every activity page favourites.
  • Page 10: Accessing The Configuration Ui Guide

    IR receiver on the device and ensure it is positioned correctly. 3.The integrity of IR data is only as good as the data that is entered into the Enado controller. Relearn codes that are causing issue and test them thoroughly from the device creator.
  • Page 11: Product Service

    The Enado Controller has a large selection of control there are other devices with statically assigned addresses outputs but this can be extended using the Enado IO on the network. Central devices should where possible Ethernet &WiFi extenders. Any Enado system can have...
  • Page 12 2. Servicing Personnel: Do not attempt to service the Limited warranty period: unit beyond that described in these operating All WyreStorm products are covered by a 3 year PARTS instructions. Refer all other servicing to authorised and LABOUR warranty. During this period there will be no servicing personnel.
  • Page 13 19. Disclaimer All images and information within this document are current and accurate as of date of creation. WyreStorm Technologies has used reasonable care in preparing the information and images included on this document, but does not warrant that such information is free of error.
  • Page 14 20. Installation Reference log WyreStorm Enado Controller Input Reference Notes Input Input IR TX Ethernet RS232 Sensor I/O Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable# Cable#...
  • Page 16 www.wyrestorm.com WyreStorm Offices US Office: 6991 Appling Farms Parkway, Suite 104, Memphis, TN 38133 Tel: +1 901 384 3575 Fax: +1 901-384-3574 EMEA Office: Unit 22, Ergo Business Park, Swindon, Wiltshire, SN3 3JW UK Tel: +44 (0) 1793 230 343 Fax: +44 (0) 1793 230 583 WyreStorm Technical Support US/Can/Mex: +1 866 677 0053 EMEA/ROW: +44 (0) 1793 238 338...

Table of Contents