Desa GMC7CF Assembly Instructions Manual page 26

Table of Contents

Advertisement

INSTALLATION
Continued
A
WARNING: Do not connect
6.
Connect one bare wire end to each terminal ("W"
this switch to any electrical
and "R")of the thermostat base (see Figure 34).
source! Electrical shock and/or
7.
Install the base onto the wall with the pro-
fire hazard will occur.
vidprl errptve
8.
Move the temperature adjustment back and forth
to insure the bimetal is free from restrictions.
9.
Replace the cover onto the base. (Upon in-
stallation, the thermostat most be allowed to
stabilize at 100111 temperature for a minimum
of 30 minutes for proper operation).
10. Set switch on fireplace to Auto position.
11. Set the temperature adjustment to the desired
setting. This thermostat has been electroni-
cally calibrated at the factory. NV adjustment
or leveling is necessary.
Feed wires through rectangular slots
Ct
0
0
0
Figure 33- Back View of Thermostat
Base
Terminal 'W
Cr
Terminal "R"
t.L
Figure 34- Thermostat Base Terminals
"WV" and
"R"
OPTIONAL WALL SWITCH - GWMS2
A
WARNING: Read and follow
installation Instructions. Instal-
lation should be done by a quali-
fied installer familiar with low-
voltage wiring procedures.
I. Connect one terminal of
25
ft. wire to bottom
contact of switch (see Figure 32. page 20).
2.
Connect remaining wire terminal to the "TIT'
terminal on the control valve. Make sure that
wire terminals are in the positions on your unit
as pictured in Figure 32, page 20.1f wires are
not "crossed" the thermostat will not work.
3.
Route the
25
ft. wire to a convenient location
to mount your wall switch (no outside walls).
A
WARNING: Do not connect
the switch to a power source.
Electrical shock
and/or fire
haz-
ard will occur.
IMPORTANT'
The wire may be shortened but
must not be lengthened.
4.
Connect one bare wire end to each of the ter-
minals of the provided wall switch.
5.
Install the wall switch and cover in the wall.
INSTALLING LOG SET AND
SCREEN
I. Remove log packaging material and discard
packaging. Gently place log on burner sup-
port (see Figure 35). The log should fit flat
against top of burner support and log locator
tabs fit into the slots under the log. Do not
allow log to contact flame. If flame contacts
log, soot will he created.
2. Reattach screen by placing the notches in the
screen frame over the shoulder screws and
pushing down.
Shoulder
Screen
Burner Support
-
with Log
Locator Tabs
Figure 35 - Installing Log and Screen
113110-01B
www.clesatech.com
21

Advertisement