9. Maintenance
(1) Replacing the fuse
↔ ↔ 200V voltage specification changeover
↔ ↔
(2) 100V ↔
3-phase 200/220/240V type and single-phase 100/110/120V type can be changed over by changing the power
source cable and changing over of the jumper.
Changeover of jumper
200V setting
100V setting
The machine uses the following three fuses:
Change over the jumper in accordance with the voltage
used.
For the change of the connection of power source cable,
refer to the item (Instruction manual (2)) of "Connecting
the power source cord".
(Caution) When a wrong connection such as putting
Jumper
– 80 –
For pulse motor power supply protection
5A (time-lag fuse)
For solenoid and pulse motor power supply pro-
tection
3.15A (time-lag fuse)
For control power supply protection
2A (fast-blow type fuse)
200V type voltage at the time of setting
100V type or the like is performed, the
printed circuit board is broken. Perform
the change of connection after checking
the voltage used.