Napoleon GD70NT Installation And Operation Instructions Manual

Napoleon GD70NT Installation And Operation Instructions Manual

Vented gas fireplace heater direct vent millivolt system
Hide thumbs Also See for GD70NT:

Advertisement

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
VENTED GAS FIREPLACE HEATER
DIRECT VENT MILLIVOLT SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS FOR:
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / AGA / CGA METHODS
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
Installation and service must be performed by a qualified installer, service agency
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
NATURAL GAS MODEL
PROPANE GAS MODEL
FOR YOUR SAFETY
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
or the gas supplier.
www.napoleonfireplaces.com • ask@napoleon.on.ca
GD70NT
GD70PT
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
1
W415-0272 / C / 05.08.03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GD70NT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Napoleon GD70NT

  • Page 1 CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS VENTED GAS FIREPLACE HEATER DIRECT VENT MILLIVOLT SYSTEM INSTALLATION AND OPERATION INSTRUCTIONS FOR: GD70NT NATURAL GAS MODEL GD70PT PROPANE GAS MODEL CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / AGA / CGA METHODS WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 2: Table Of Contents

    TABLE of CONTENTS PG2-5 INTRODUCTION OPTIONAL BLOWER Warranty INSTALLATION Dimensions General Instructions OPTIONAL FAN & General Information THERMOSTATIC SENSOR Care of Glass & Plated Parts VENTING 17-18 OPERATION / MAINTENANCE Vent lengths Operating Instructions Special Installation Example Maintenance Air Terminal Locations ADJUSTMENTS 8-12 INSTALLATION/FRAMING...
  • Page 3 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station.
  • Page 4: General Instructions

    FIGURE 1 Purge all gas lines with the glass door of the fireplace open. WARNING: The door for this fireplace is sold Assure that a continuous gas flow is at the burner before separately. The door must be installed and closing the door.
  • Page 5: Care Of Glass & Plated Parts

    This fireplace may be installed in an aftermarket per- CARE OF GLASS, AND PLATED PARTS manently located, manufactured (mobile) home, where not prohibited by local codes. Do not use abrasive cleaners to clean plated parts. Buff This fireplace is only for use with the type of gas indi- lightly with a clean dry cloth.
  • Page 6: Vent Lengths

    For optimum performance, it is recommended SPECIAL INSTALLATION EXAMPLE that all horizontal runs have a minimum ¼ inch When a horizontal offset is required in a through-the-roof rise per foot. installation, the following procedure for vent length calcu- Wolf Steel rigid and flexible venting systems must lations must be followed: not be combined.
  • Page 7 AIR TERMINAL INSTALLATIONS FIGURE 6 INSTALLATIONS CANADIAN U.S.A. 12 INCHES 12 INCHES Clearance above grade, veranda porch, deck or balcony. Clearance to windows or doors that open. 12 INCHES 9 INCHES Clearance to permanently closed windows. 12 INCHES* 12 INCHES* Vertical clearance to ventilated soffit located above the terminal within 18 INCHES** 18 INCHES**...
  • Page 8: Wall & Ceiling Protection

    INSTALLATION WALL AND CEILING PROTECTION For optimum performance it is recommended that all VERTICAL INSTALLATION horizontal runs have a minimum ¼ inch rise per foot using flexible venting. This application occurs when venting through a For safe and proper operation of the fireplace, follow the FIGURE 9 roof.
  • Page 9: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS VERTICAL AIR TERMINAL INSTALLATION 1. Fasten the roof support FIGURE 14 to the roof using the Use only approved aluminum flexible liner kits screws provided. The marked " Wolf Steel Approved Venting" as roof support is optional. identified by the stamp only on the 7"...
  • Page 10: Fireplace Vent Connection

    FIREPLACE VENT CONNECTION FIGURE 17 1. Install the 4 inch diameter aluminum flexible liner to the fireplace. Secure with 3 screws and flat washers. Seal the joint and screw holes using the high temperature sealant provided. 2. Install the 7 inch diameter aluminum flexible liner to the fireplace.
  • Page 11: Gas Installation

    8. Continue adding rigid venting sections, sealing and FRAMING securing as above. Attach a 4" collapsed telescopic pipe to the last section of rigid piping. Secure with screws and It is best to frame your fireplace after it is positioned and seal.
  • Page 12: Mantle Installation

    FIGURE 26 It is not necessary to install a hearth extension, but the TILES fireplace should be raised up to be flush with either the BLACK PAINTED hearth or the finished floor. FIREPLACE SURFACE When roughing in the fireplace, raise the fireplace to accommodate for the thickness of the finished floor mate- rials, i.e.
  • Page 13 GDLV LOUVRE INSTALLATION L38 LOUVRE INSTALLATION Remove the pro- FIGURE 33 a-c tective plastic wrap from the louvres LOUVRE and install as il- BRACKET lustrated. Clip each upper louvre into a slot louvre bracket. Ensure that the louvres are centered within the opening.
  • Page 14: Face Plate Installation

    FACE PLATE INSTALLATION Attach a screw and spacer as illustrated to either side at the top and bottom of the corner posts. 3. Position log #3 to the right of the firebox using the two locating studs. Log #4 is located using the stud on the narrow end as well as a notch which will nest onto the second grate post from the left.
  • Page 15: Optional Blower Installation

    OPTIONAL BLOWER INSTALLATION INSTALLATION TO BE DONE BY A QUALIFIED IN- Attach the connectors from the black and red wires to the STALLER and must be electrically connected and grounded blower. in accordance with local codes. In the absence of local Attach and secure the variable speed switch using the nut codes, use the current CSA C22.1 provided.
  • Page 16 OPTIONAL FAN INSTALLATION Slide the fan assembly past the controls and and into the ELECTRICAL INSTALLATION TO BE DONE BY A QUALI- clip. Secure using the lock washer and nut provided. FIED INSTALLER and must be connected and grounded Plug the harness cord into the receptacle. in accordance with local codes.
  • Page 17: Operation / Maintenance

    OPERATION / MAINTENANCE After extended periods of non-operation such as following OPERATING INSTRUCTIONS a vacation or a warm weather season, the fireplace may When lit for the first time, the fireplace will emit a slight emit a slight odour for a few hours. This is caused by dust odour for a few hours.
  • Page 18: Maintenance

    MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER TURN OFF THE GAS AND ELECTRICAL POWER TURN OFF THE GAS AND ELECTRICAL POWER TURN OFF THE GAS AND ELECTRICAL POWER TURN OFF THE GAS AND ELECTRICAL POWER 3. Check to see that all burner ports are burning. Clean BEFORE SERVICING THE FIREPLACE.
  • Page 19: Replacements

    REPLACEMENTS Contact your dealer or the factory for questions concerning 1. M & S ODEL ERIAL UMBER OF FIREPLACE prices and policies on replacement parts. Normally all parts 2. I NSTALLATION DATE OF FIREPLACE can be ordered through your Napoleon dealer or distributor. 3.
  • Page 20 W415-0272 / C / 05.08.03 * WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
  • Page 21: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN SYMPTOM PROBLEM TEST SOLUTION Main burner flame Blockage in vent. - remove blockage. In really cold conditions, ice buildup may occur is a blue, lazy, on the terminal and should be removed as required.
  • Page 22 SYMPTOM PROBLEM TEST SOLUTION - connect a jumper wire across the wall switch terminals; if main Themostat or switch is de- Pilot burning; no burner lights, replace switch / thermostat. fective. main burner; gas knob Wall switch wiring is defec- - disconnect switch wires &connect a jumper wire across terminals is on 'HI';...
  • Page 23 W415-0272 / C / 05.08.03...
  • Page 24 W415-0272 / C / 05.08.03...