General Information; Rating Plate Information - Napoleon GVF40P Installation And Operating Instructions Manual

Vent free millivolt system
Table of Contents

Advertisement

If the appliance is installed directly on carpeting, vinyl tile or other
combustible material other than wood fl ooring, the appliance shall be installed on a metal or wood panel
extending the full width and depth. NOTE: This does not apply to stoves.
* Air shortage caused by an inadequate air supply, improper log positions, the addition of foreign or
unapproved materials or the failure to properly maintain the appliance, may result in incomplete combustion of
the fuel. Incomplete combustion results in soot being deposited inside the fi rebox as well as surfaces outside
the appliance. If any soot deposits are observed, shut off the appliance immediately and arrange for it to be
serviced by a qualifi ed technician.
2.3

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
Altitude (FT)
Max. Input (BTU/HR)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply Pressure
Manifold Pressure (Under Flow Conditions)
When the appliance is installed at elevations above 2,000ft, and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of
4% for each additional 1,000ft.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
This appliance is equipped with a pilot light safety system referred to as an oxygen depletion sensor and is
designed to turn off the appliance if not enough fresh air is available.
2.4

RATING PLATE INFORMATION

For rating plate
location, see
"INSTALLATION
OVERVIEW" section.
This illustration is for
reference only. Refer
to the rating plate
on the appliance for
accurate information.
THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET,
PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME, WHERE
NOT PROHIBITED BY LOCAL CODES. THIS APPLIANCE IS ONLY FOR
USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE.
THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER
GASES.
MODEL GVF40-N / CVF400-N
0-2000FT (0-610m)**
30,000 BTU/h
20,000 BTU/h
MANIFOLD PRESSURE: 3.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
OPERATING PILOT OXY PROTECTOR: #8214
WARNING: FIREPLACE SCREENS MUST BE CLOSED WHILE IN OPERATION.
COME IN CONTACT WITH FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. DO NOT USE BLOWER INSERT, HEAT EXCHANGER INSERT OR
OTHER ACCESSORIES NOT APPROVED FOR USE WITH THIS HEATER. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTAINANCE CAN CAUSE PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. REFER TO THE OWNER'S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE. INSTALLATION AND SERVICE MUST BE
PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS:
BLE MATERIALS:
BLE MATER
TOP / SIDES / BACK / FLOOR
0
0"
RECESSED DEPTH
25
25¼"
25¼
¼
"
"
H
MANTEL
5"*
5"*
5"*
WOLF STEEL LTD.
24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA
APPLIANCE
NG
0-2,000
30,000
4.5" Water Column 11" Water Column
7" Water Column
3.5" Water Column 10" Water Column
CERTIFIED UNDER: ANSI Z21.11.2a-2008 VOLUME II, UNVENTED ROOM HEATER
9700539 (WSL)
4001658 (NAC)
ALTITUDE
INPUT
REDUCTED INPUT
D INPUT
D INPUT
SIT CONTROL: #820637
** ABOVE 2,000FT, CONSULT LOCAL AUTHORITY HAVING JURISDICTION.
ONSULT LOCAL AUTHORITY HA
ONSULT LOCAL AUTHORITY H
NOT FOR USE WITH SOLID FUEL.
T FOR USE WITH SOL
OR USE WITH SOL
E CLOSED WHILE IN OP
E CLOSED WHILE IN O
PLIED BY THE MANUFACTURER W
LIED BY THE MANUFACTURER W
HIS HEATER. IMPROPER INSTALLA
HEATER. IMPROPER INSTALL
R TO THE OWNER'S INFORMATION
E OWNER'S INFORMATIO
AGENCY OR THE GAS SUPPLIER.
R THE GAS SUPPLIER.
8 CAN
4.2D
LP
0-2,000
30,000
13" Water Column
ER
ER
THIS IS A GAS-FIRED UNVENTED ROOM HEATER THAT REQUIRES
UNVENTED
UNVENTED
ADEQUATE COMBUSTION AND VENTILATION AIR. THIS UNIT IS NOT
USTION AND VEN
USTION AND VENT
APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
R BEDROOM, BATHROO
R BEDROOM, BATHROO
INSTALLATION.
N.
4001657 (NGZ)
657 (NGZ)
57 (NG
4001659 (WUSA)
01659 (WUSA)
1659 (WUS
MODEL GVF40-P / CVF400-P
MODEL
MODEL
0-2
0-2
0-2000FT (0-610m)**
2
28,500 BTU/h
22,000 BTU/h
MANIFOLD PRESSURE: 10" WATER COLUMN
MANIFOLD P
M
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
MINIMUM
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
MAXIM
M
SIT
SIT C
SIT CONTROL: #820636
OPERATING PILOT OXY PROTECTOR: #8404
OP
O
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL
* MAXIMUM HORIZONTAL EXTENSION: 2".
SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS.
ELECTRICAL RATING: 115V, 0.82AMP, 60HZ
OPTIONAL FAN KIT: GZ550-KT
SERIAL NUMBER:
GVF40 / CVF400
W415-0810 / C / 04.26.12
7