11A-6-6
4G1 ENGINE (E - W) -
E
E
Mitsubishi Motors Corporation
Mitsubishi Motors Corporation
"FA THERMO VALVE INSTALLATION
(1) If the thermo valve is to be reused, apply the specified
1EN0511
"GA THERMOSTAT HOUSING INSTALLATION
(1) Remove the old liquid gasket from the cylinder head
(2) Apply liquid gasket to the thermostat housing mounting
"HA WATER OUTLET FITTING INSTALLATION
(1) Remove the old liquid gasket from the thermostat housing
(2) Apply liquid gasket to the water outlet fitting mounting
Nov. 1995
Aug. 2000
Water Pump and Water Hose
sealant to its thread.
Specified sealant:
Mitsubishi Genuine Part No. MD970389 or
equivalent.
(thermostat housing mounting surface) and the thermostat
housing.
surface by squeezing it to a thickness of 3 mm.
Specified sealant:
Mitsubishi Genuine Part No. MD970389 or
equivalent.
Caution
Squeeze the liquid gasket uniformly so that there is
no break in the gasket nor is there too much gasket.
(water outlet fitting mounting surface) and the water outlet
fitting.
surface by squeezing it to a thickness of 3 mm.
Specified sealant:
Mitsubishi Genuine Part No. MD970389 or
equivalent.
Caution
Squeeze the liquid gasket uniformly so that there is
no break in the gasket nor is there too much gasket.