FIREMAN'S SWITCH CONNECTION
NOTICE: When using a timer and Fireman's Switch, the
heater's power supply should come from the load side of
the timer.
FIGURE 24: Open Control Box Cover
FIGURE 25: Fireman's Switch Connections
N T
V E
S
E S
P R
T A
B
O T
P IL
Connect the Fireman's switch to the heater as follows:
1. Turn off power to heater at main circuit breaker panel.
2. Unbolt and remove the upper jacket halves (see Figure
3, Page 5).
3. Open control box cover (see Figure 24).
4. Remove the factory-installed jumper between the
Fireman's Switch terminals (see Figure 25).
5. Connect the wires between the Fireman's Switch termi-
nals on the heater and those on the time clock using
14 gauge wire with a minimum 3/64" thick insulation
rated for a temperature rise of at least 105°C. Route the
wires out through the knockout on the bottom of the
Control Box. Use a 90° conduit el and conduit run out
through the cutout on the Lower Enclosure, next to the
the Junction Box (see Figure 23).
6. Reinstall and bolt up the jacket halves.
The fuse for the Fireman's Switch is 1.25 amp 1-1/4x1/4"
fast blow fuse, available locally.
MAXIMUM TEMPERATURE SET POINT
1. Unbolt and remove upper jacket halves (see Figure 3,
Page 5).
2. Depress clips and remove control panel assembly
dome (see Figure 9, Page 10).
3. Push the Max. Temp. Set Point button on the back of
the control panel (see Figure 26). The following
sequence should happen:
A. The unit will come on and the POOL ON light will
come on.
B. Press the
Temp or
panel) to set maximum pool temperature.
C. Wait 5 seconds; the POOL ON light will go off and
the SPA ON light will come on.
D. Press the
Temp or
panel) to set maximum spa temperature (set temper-
ature to 104° F or less).
E. Wait 5 seconds; the SPA ON light will go off and the
unit will shut down.
4. Reinstall and bolt up the jacket halves.
FIGURE 26: Max Temperature Set Point Controls