Water Connections - STA-RITE 200K BTU/HR Owner's Manual

Sr pool and spa heater natural gas / lp gas; 200k btu/hr; 333k btu/hr; 400k btu/hr
Hide thumbs Also See for 200K BTU/HR:
Table of Contents

Advertisement

WATER CONNECTIONS

The heater requires proper water flow and pressure for its
operation. See Figures 15 and 16 for the recommended
installation. The filter pump discharges to the filter, the fil-
ter discharges to the heater, and the heater discharges
directly to the pool or spa.
A manual bypass valve should be installed across the
heater when the pump flow exceeds 120 GPM. See
instructions below for setting of the manual bypass.
Make sure that the outlet plumbing from the heater con-
tains no shut-off valves or other flow restrictions that could
prevent flow through the heater (except as noted below).
To switch flow between the pool and spa, use a diverter
valve. Do not use any valve that can shut off the flow.
Do not use a shut-off valve to isolate the heater unless it is
below the level of the pool or spa.
Install a check valve if there is a possibility of back-siphon-
ing through the heater when the pump is off.
NOTICE: Improper operation of chemical feeders can
cause severe damage to the heater which is not covered by
the warranty. Either equip chemical feeders with an anti-
siphon device to prevent chemicals from siphoning into the
heater if the pump shuts off, or install the chemical feeder
downstream of the heater.
WATER PIPING
Connect the heater directly to 2" PVC pipe, using the inte-
gral unions provided. The low thermal mass of the heater
will prevent overheating of the piping even if the pump
shuts down unexpectedly. Heat sinks are not required.
FIGURE 15:
Typical installation
SYSTEM 3
Modular Media
Filter
To Filter
Inlet
Cool Water
In From Pool
Main
Drain
Pool
From Pool
FIGURE 16: Typical pool piping layout
WATER FLOW RATE
Maximum and minimum water flow rates required by the
heater are listed below:
Table 8: Maximum and Minimum
Flow Rate in GPM
Model
Minimum Flow
200
333
400
From Filter Outlet
to Heater
Inlet
Positive Seal
Check Valve
Cool Water
In From Spa
16
3-Way
Chlorinator
Valve
Heater
Filter
Spa
Pump
3-Way
Valve
Maximum Flow
20
120
33
120
40
120
Warm Water
Out to Pool or Spa
To Pool
To Spa
Sanitizer
3-Way
Valve

Hide quick links:

Advertisement

Table of Contents
loading