Convection Temperature Test

NOTE: It is absolutely necessary to own and use a
thermocouple type oven tester to accurately
measure oven temperature. No other type of
thermometer can take its place.
NOTE: Before testing an oven to check calibration,
inspect the RTD for proper mounting.
1. Place one wire rack in center position. Remove any
other racks and utensils.
2. Clip thermocouple to the center rack and run lead
outside oven door, or wrap thermocouple around
rack and have tip of thermocouple extend upward
towards top of cavity approximately 1".
3. Press PREHEAT ON/OFF pad.
4. Press PROGRAM SAVE pad.
5. Press TEMP pad.
6. Enter 230°C (450°F).
7. Allow oven to cycle one time.
8. Record high and low peaks from next two cycles.
NOTE: Display does not indicate if heating elements
are on or off.
Fahrenheit Example:
LOW
Cycle
1
440°F
Cycle
2
439°F
879°F
1800°F / 4 = 450°F average temperature
Celsius Example:
LOW
Cycle
1
230°C
Cycle
2
230°C
450°C
+
930°C / 4 = 230°C average temperature
If the average temperature is too high or too low the
oven temperature offset needs to be calibrated.
RS5320016
Rev. 0
HIGH
460°F
461°F
+
921°F = 1800°F
HIGH
240°C
240°C
480°C = 930°C

Convection Temperature Calibration

NOTE: It is normal for the average oven temperature to
vary from the oven setting by as much as 25°F
(14°C). Difference will not effect cooking since
recipes are written with this difference in mind.
Calibration
NOTE: Door must be closed.
1. Press HIDDEN PAD.
2. Press pads 1,3,5,7, 9.
3. Press "0" pad.
ITEM
STG
QTY
1
2
3
C M
4
LMT
PREHEAT
NOTE: Display will show the current offset setting.
4. Press the "0" pad to change the offset.
NOTE: Offset temperature range is +40°F to -40°F
and advances in 2 and 3° increments.
NOTE: Offset temperature range is +22°C to -22°C
and advances in 1 and 2° increments.
5. Press STOP/RESET pad to save offset changes.
NOTE: Retest the oven after any offset changes are
made.
Fahrenheit Example:
• Oven temperature is set for 450°F.
• Average of temperature test is 475°F.
• Offset setting must be reduced by 25°F.
• If offset is shown as 10°, press the "0" pad until -15 is
shown in the display (10 – 25 = -15).
Celsius Example:
• Oven temperature is set for 230°C.
• Average of temperature test is 240°C.
• Offset setting must be reduced by 10°C.
• If offset is shown as 5°, press the "0" pad until -5 is
shown in the display (5 – 10= -5).