Display Diagnostics; Error Codes - Amana ACE530 Service

International commercial combination/convection microwave oven with 230 v, 50 hz
Table of Contents

Advertisement

Display Diagnostics

All repairs as described in this troubleshooting section are to be performed only after the caution procedures one
through eight listed below have been followed.
1. Check grounding before checking for possible causes.
2. Be careful of the high voltage circuit.
3. Discharge high voltage capacitor.
4. When checking the continuity of the switches or the high voltage transformer, disconnect one lead wire from
these parts and then check continuity with the AC plug removed. To do otherwise may result in a false reading
or damage to your meter.
5. Do not touch any parts of the circuitry on the P.C. Board circuit since static electric discharge may damage this
control panel. Always touch yourself to ground while working on this panel to discharge any static charge in
your body.
6. 208/230 VAC is present in the high voltage circuit board, power relay and primary circuit of low voltage
transformer.
7. When troubleshooting, be cautious of possible electrical hazard.
8. When testing convection operation, convection fan may start at any time or if oven is hot.

Error Codes

During operation, the display may show the following service codes:
NOTE: Before scheduling service for any error codes, instruct customer to unplug oven for 1 minute, reconnect
power, and retest. If unit operates properly, no service call is required.
Display
Err1
Checksum Error
Err2
Hardware Problem
Err3
Hardware Problem
Err4
Hardware Problem
Err5
Defective Touch Panel
Err6
RAM Error
Err7
Error with RTD circuit
If power level shows
0 - Uncalibrated ..................................
1 - Shorted RTD circuit.......................
2 - Open RTD circuit ...........................
HOT
Door
Door Interlock Primary Switch
RS5320016
Rev. 0
!
CAUTION
Description
16
Corrective Action
See note above.
Replace H.V. board.
See note above.
Verify wiring at H.V. board.
If wiring is good, replace H.V. board.
May be a failed Touch Panel. Verify before replacing.
See note above.
Verify wiring at H.V. board.
If wiring is good, replace H.V. board.
May be a failed Touch Panel. Verify before replacing.
See note above.
Check green jumper at J8 connector on H.V. board.
If jumper is good, replace H.V. board.
See note above.
If Touch Panel is pressed for more than 30 seconds,
this error code will appear.
Replace touch panel.
See note above.
Replace H.V. board.
See note above.
Replace H.V. board.
Check RTD and wiring to H.V. board.
Check RTD and wiring to H.V. board.
See note above.
Open TCO.
Convection motor inoperative.
Restricted air filter.
H.V. board inoperative.
Broken or loose wire.
See note above.
Verify latch mechanism moves freely on door.
Verify J1 connector on display board is properly
seated.
Test interlock switch assembly and perform door
adjustment if necessary.
Replace interlock switch assembly if failed.